Toshiba F30 Personal Computer User Manual


 
Appendix J Maintenance of TOSHIBA RAID Appendices
6. Put the cursor on the “DONE” and press [Enter] key. Pressing “OK” in
[Confirmation] store the change.
CAUTION: When the array is initialized, the data of drive is lost.
Start Rebuild
Selecting of this option starts rebuilding. [Start Rebuild] is displayed only in the RAID-
1 condition of with “OFFLINE” drive that has same or more size of capacity as the
array in the condition of “Optimal” or “Degraded”.
During halt of rebuilding, [Resume Rebuild] is displayed instead of [Start Rebuild].
The procedure to rebuild drives is as follows.
1. Put the cursor to the [Start Rebuild] in the main menu of Indent Utility and press
[Enter] key.
2. Select the direction to rebuild in [Rebuild Direction] menu and press [Enter] key.
When the array is “Degraded”, the choice is only is one.
QOSMIO F30 Maintenance Manual (960-555) [CONFIDENTIAL] J-15