Toshiba MR-3022 Scanner User Manual


 
MR-3018/3020/3021/3022 © 2005 - 2011 TOSHIBA TEC CORPORATION All rights reserved
DISASSEMBLY AND ASSEMBLY
4 - 22
(4) Release the harness from 3 harness clamps.
(5) Remove 1 E-ring and take off the bushing.
Fig. 4-60
(6) Disconnect 3 terminals of the switch.
(7) Remove 4 screws, and then take off the
bracket.
Note: Note:
When connecting the terminal, make sure
that the color of the harness is correct.
Fig. 4-61
(8) Take off the timing belt, bushings and pulley.
Fig. 4-62
E-ring Bushing
Harness clampHarness clamp
Bracket
Red
White
Black
Pulley
Bushing Timing belt