Toshiba MR-3022 Scanner User Manual


 
© 2005 - 2011 TOSHIBA TEC CORPORATION All rights reserved MR-3018/3020/3021/3022
ADJUSTMENT
5 - 17
5
5.6 Adjustment of Copy Ratio
Note: Note:
Check if the image adjustment for the equipment is performed properly before this adjustment of
the RADF.
(See the Service Manual or Service Handbook of the applicable equipment.)
Also, the RADF position and height shall be adjusted properly.
[A] Checking
Check the image using the chart (original) with vertical and horizontal lines in the following procedure.
(1) Place the chart provided as an original with its face up on the original tray of the RADF.
(2) Press the [START] button.
(3) Superimpose the chart on the copy and check the image dimension “I”.
[B] Adjustment
(1) Turn the power ON while pressing [0] and [5] simultaneously.
(2) Key in [357] *1 / [3042] *2 and then press the [START] button.
*1 : For e-STUDIO352/353/452/453
e-STUDIO281c/351c/451c,
e-STUDIO2500c/3500c/3510c,
e-STUDIO2330C/2820C/2830C/3520C/3530C/4520C,
e-STUDIO202L/203L/232/233/282/283,
e-STUDIO205L/255/305/355/455
*2 : For e-STUDIO2040C/2540C/3040C/3540C/4540C,
e-STUDIO206L/256/306/356/456
If the copy image dimension “I” is larger than the chart dimension, enter a value smaller than
the current one.
If the copy image dimension “I” is smaller than the chart dimension, enter a value larger than
the current one.
Fig. 5-30
I
11/12