Toshiba MR-3022 Scanner User Manual


 
MR-3018/3020/3021/3022 © 2005 - 2011 TOSHIBA TEC CORPORATION All rights reserved
TROUBLESHOOTING
6 - 2
6.2 Troubleshooting for Electrical Errors
1) RADF does not work (except in the case of a paper jam or when the cover is open)
2) Communication error
3) Size detection error
Interface harness connected properly?
NO Connect the harness properly or replace it
YES
DC+5V supplied to CN70-2, 3pin?
NO Connect the harness properly or replace it
YES
DC+24V supplied to CN70-6, 7pin?
NO Connect the harness properly or replace it
YES
DC+24V supplied to CN72-4pin?
NO Check or replace the jam access cover switch
YES
Empty sensor is ON when there is paper?
NO Check or replace the empty sensor
YES
Check or replace the RADF board
Interface cable normal?
NO Replace the interface cable
YES
Check or replace the RADF board and check the equipment
Original tray sensor is ON when there is paper?
NO Replace the sensor or harness
YES
Registration roller does not catch the original?
YES Clean the roller with alcohol or replace
NO
Original width detection sensor-1 is ON when there is paper?
NO Replace the sensor or harness
YES
Original width detection sensor-2 is ON when there is paper?
NO Replace the sensor or harness
YES
Check or replace the RADF board
11/12