Tripp Lite SU10000RT3UG Power Supply User Manual


 
Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail: saleshelp@tripplite.com
Model #: SU10000RT3UG
SmartOnline Expandable Rack/Tower UPS System - Online, double-conversion protection for mission critical
applications
Highlights
Global 10,000VA/10kVA on-line 6U rack/tower UPS with expandable runtime
(3U Power Module + 3U Battery Pack)
Zero transfer time, on-line, double-conversion and economy-mode operation
supported
Detachable PDU with manual bypass switch enables hot-swap UPS
replacement without powering off connected loads
200, 208, 230 or 240V selectable input/output voltage, with hardwire input and
six individually breakered C19 outlets
2% output voltage regulation over an input voltage range of 156 to 296
Simultaneous-use RS232 and contact closure monitoring ports, SNMP/Web
Card Slot and EPO interfaces
$250,000 Ultimate Lifetime Insurance (USA, Puerto Rico & Canada only)
Description
Global 10,000VA (10kVA) on-line, double-conversion UPS system for critical server, network and telecommunications equipment. Installs in only 6
rack spaces (3U power module and 3U battery pack); maximum installed rack depth of 32.5 in. Worldwide shipping version with 6 C19 outlets.
Maximum installed rack depth of 32.5 inches. Expandable battery runtime with optional BP240V10RT3U external battery packs. Full-time sine wave
200, 208, 220, 230, or 240V +/-2% output. Actively converts raw incoming AC power to DC, then re-converts output back to completely regulated,
filtered AC output. Operates continuously without consuming battery power during brownouts to 156V and overvoltages to 276V. Highly efficient
operation in optional economy mode setting, saving BTU heat output and energy costs. Standard 3-wire 208V hardwire input connection; 6
individually breakered C19 output receptacles. Detachable input-output PDU module with manual bypass switch enables hot-swap UPS replacement
without disrupting power to connected equipment. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery
operation. Network management interfaces support communications via RS-232, contact-closure port and optional SNMPWEBCARD slot. Supports
detailed monitoring of equipment load levels, self-test data and utility power conditions via network interfaces. Includes PowerAlert monitoring
software and complete cabling. Emergency Power Off (EPO) interface. Front panel LEDs provide at-a-glance confirmation of line power status,
battery power status, AC-to-DC conversion, DC-to-AC conversion, bypass mode and output power status. LED/LCD display panel rotates for better
viewing in rackmount or tower configurations. Detailed LCD panel with scroll buttons provides detailed diagnostic test information at startup and
during self tests, plus real-time data on input and output voltage, frequency (Hz), load percentage and battery charge level. Audible alarm. Self-test.
Fault-tolerant auto-bypass mode. 4-post rackmount accessories and 2-9USTAND tower kit included; 2POSTRMKITWM 2-post rackmount hardware
accessories available. Field-replaceable, hot-swappable power module and external battery packs. Attractive all-black color scheme. 2-year
warranty and $250,000 connected equipment insurance; extended warranty and service contracts available.
Applications
Ideal for protection of sensitive electronics in any application calling for upright tower or 19 inch rackmount UPS protection. Common
applications include any mix of servers, workstations, hubs, routers, concentrators, IP telephony and traditional PBX switching systems