Tyco Electronics 0-1591093-X Switch User Manual


 
24 and 16 Port Smart Switch II – User Manual Page 9
These option modules are installed as described on page 6.
The following plug-in fibre modules are available as field installable
accessories for this switch: -
Product Part Number
100 Fx Module with SC multimode connectors 0-1591094-0
100 Fx Module with ST multimode connectors 0-1591095-0
100 Fx Module with SC singlemode connectors 0-1591096-0
Dual Gigabit Sx Multimode SC connectors 0-1591097-0
Dual Gigabit Lx Singlemode SC connectors 0-1591098-0
Dual Gigabit Copper Module 1000BaseT 2-1591019-0
Table 1 - Uplink Option Ports
Optical Link Wavelength
The 100 Fx optional modules operate at the 1310nm optical
wavelength. The Gigabit Lx Singlemode module operates at
1310nm and the Gigabit Sx multimode module operates at 850nm
optical wavelength.
Optical Link Calculations
The maximum distance between any two fibre optic devices is
determined by a number of factors including optical link loss, the
type and number of patch cords and joints in the link, the launch
power of the transmitter and the sensitivity of the receiver. These
variables make calculating the maximum working distance between
two units quite difficult and so it is best to design networks using
optical loss budgets rather than using just working distance.
Dual Gigabit 1000BaseT copper module
The RJ-45 will auto-negotiate 100Base-TX and Gigabit 1000T
connections. Support for Auto MDI/MDIx is also provided.
It should be noted that Gigabit 1000T (1000Mbps) connection must
use Cat-6 or Cat5-E twisted cable pair cable. If use cat-5 cable is
used then support 100Mbps link speed is available only. The
available link distance is up to 100Meters.
Product Number 0-1591093-x 0-1591047-x Issue 1
© Tyco Electronics 2005