Ultra Products ULT33062 Power Supply User Manual


 
Uninterrupted
Power Supply (UPS)
The Ultimate Power Protection!
If you're looking for the most complete, technologically advanced power protection
unit for the money, the Ultra UPS line is exactly what you need. An Ultra UPS is an
absolute must for anyone running a small server, workstation or a powerful PC. We're
so confident that our UPS will offer you ultimate power protection, it carries a
$125,000 guarantee against damage to any equipment connected to the UPS. You
simply cannot afford to cut corners when it comes to safeguarding your valuable
equipment, and these UPS's deliver the comprehensive protection for computer,
peripherals and data files at a remarkably low price.
300VA 500VA
Gneral Sku ULT33061 ULT33062
Backup Time 4-6 minutes (a PC with 15” CRT monitor)
8-12 minutes
(
a PC with 15” LCD monitor
)
7-9 minutes (a PC with 15” CRT monitor)
14-16 minutes
(
a PC with 15” LCD monitor
)
Net Weight Kg (lbs) 1.9
(
4.2
)
2.58
(
5.67
)
Digital Display No No
Output Watts 150 250
UPS Capacity 300VA 500VA
No. of Sockets St
y
le A UPSx3
,
B
yp
assx3 St
y
le A UPSx3
,
B
yp
assx3
Voltage (Battery) Simulated sine wave at 120V +/- 5% Simulated sine wave at 120V +/- 5%
Frequency (Battery) 50 or 60Hz +/- 0.3Hz 50 or 60Hz +/- 0.3Hz
Transfer Time 2-4 milliseconds
,
includin
g
detection time 2-4 milliseconds
,
includin
g
detection time
Input Voltage (Single Phase) 120V +15%/-20% at line in
p
ut 120V +15%/-20% at line in
p
ut
Frequency 50 or 60Hz +/- 10%
(
auto sensin
g)
50 or 60Hz +/- 10%
(
auto sensin
g)
Protection Unit Input Circuit breaker for overload & short circuit
p
rotection Circuit breaker for overload & short circuit
p
rotection
Overload Protection AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously.
Backup Mode: If load exceeds 110% of nominal for 1
second, UPS shuts down automatically.
AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously. If load exceeds 120% of nominal for
30 seconds, 130% for 3 seconds, UPS shuts down
automatically.
Back up Mode: If load exceeds 105% of nominal for 20
seconds, 120% for 10 seconds, 130% for 3 seconds,
UPS shuts down automaticall
y
.
Short Circuit UPS out
p
ut shuts off immediatel
y
UPS out
p
ut shuts off immediatel
y
Surge Protection 1140 Joules
,
2ms 1140 Joules
,
2ms
Battery Type Sealed, maintenance-free lead acid battery, with 3-6
y
ears t
yp
ical lifetime
Sealed, maintenance-free lead acid battery, with 3-6
y
ears t
yp
ical lifetime
Typical Recharge Time 4 hours
(
to 90% of full ca
p
acit
y)
6 hours
(
to 90% of full ca
p
acit
y)
Protection Automatic self-test, Over discharge protection, short
circuit
p
rotection b
y
fuse
Automatic self-test, Over discharge protection, short
circuit
p
rotection b
y
fuse
Interface USB Battery low detecting, UPS on/off scheduling AC
in
p
ut/out
p
ut
p
ower status dis
p
la
y
.
Battery low detecting, UPS on/off scheduling AC
in
p
ut/out
p
ut
p
ower status dis
p
la
y
.
Alarm Battery Backup Slow bee
p
in
g
sound ever
y
4 seconds Slow bee
p
in
g
sound ever
y
4 seconds
Battery Low Ra
p
id bee
p
in
g
sound ever
y
second Ra
p
id bee
p
in
g
sound ever
y
second
Abnormal Charge AC Mode: Ra
p
id bee
p
in
g
sound ever
y
0.5 second AC Mode: Ra
p
id bee
p
in
g
sound ever
y
0.5 second
Overload Continuous bee
p
in
g
sound Continuous bee
p
in
g
sound
Environment Ambient Operation 3,500 meters max. elevation, 0-95% humidity non-
condensin
g,
0-40?
3,500 meters max. elevation, 0-95% humidity non-
condensin
g,
0-40?
Audible Noise <40dBA
(
1 meter from surface
)
<40dBA
(
1 meter from surface
)
700VA 850VA
ULT33063 ULT33064
9-11 minutes (a PC with 15” CRT monitor)
17-19 minutes
(
a PC with 15” LCD monitor
)
16-20 minutes (a PC with 15” CRT monitor)
36-40 minutes
(
a PC with 15” LCD monitor
)
2.58(5.67) 4.1(9.1)
No No
350 425
700VA 850VA
St
y
le A UPSx3
,
B
yp
assx3 St
y
le A UPSx4
,
B
yp
assx4
Simulated sine wave at 120V +/- 5% Simulated sine wave at 120V +/- 5%
50 or 60Hz +/- 0.3Hz 50 or 60Hz +/- 0.3Hz
2-4 milliseconds
,
includin
g
detection time 2-4 milliseconds
,
includin
g
detection time
120V +15%/-20% at line in
p
ut 120V +15%/-20% at line in
p
ut
50 or 60Hz +/- 10%
(
auto sensin
g)
50 or 60Hz +/- 10%
(
auto sensin
g)
Circuit breaker for overload & short circuit
p
rotection Circuit breaker for overload & short circuit
p
rotection
AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously. If load exceeds 120% of nominal for
30 seconds, 130% for 3 seconds, UPS shuts down
automatically.
Back up Mode: If load exceeds 105% of nominal for 20
seconds, 120% for 10 seconds, 130% for 3 seconds,
UPS shuts down automaticall
y
.
AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously. If load exceeds 120% of nominal for
30 seconds, 130% for 3 seconds, UPS shuts down
automatically.
Back up Mode: If load exceeds 105% of nominal for 20
seconds, 120% for 10 seconds, 130% for 3 seconds,
UPS shuts down automaticall
y
.
UPS out
p
ut shuts off immediatel
y
UPS out
p
ut shuts off immediatel
y
1140 Joules, 2ms 1520 Joules, 2ms
Sealed, maintenance-free lead acid battery, with 3-6
y
ears t
yp
ical lifetime
Sealed, maintenance-free lead acid battery, with 3-6
y
ears t
yp
ical lifetime
6 hours (to 90% of full capacity) 6 hours (to 90% of full capacity)
Automatic self-test, Over discharge protection, short
circuit
p
rotection b
y
fuse
Automatic self-test, Over discharge protection, short
circuit
p
rotection b
y
fuse
Battery low detecting, UPS on/off scheduling AC
in
p
ut/out
p
ut
p
ower status dis
p
la
y
.
Battery low detecting, UPS on/off scheduling AC
in
p
ut/out
p
ut
p
ower status dis
p
la
y
.
Slow bee
p
in
g
sound ever
y
4 seconds Slow bee
p
in
g
sound ever
y
4 seconds
Ra
p
id bee
p
in
g
sound ever
y
second Ra
p
id bee
p
in
g
sound ever
y
second
AC Mode: Ra
p
id bee
p
in
g
sound ever
y
0.5 second AC Mode: Ra
p
id bee
p
in
g
sound ever
y
0.5 second
Continuous bee
p
in
g
sound Continuous bee
p
in
g
sound
3,500 meters max. elevation, 0-95% humidity non-
condensin
g,
0-40?
3,500 meters max. elevation, 0-95% humidity non-
condensin
g,
0-40?
<40dBA
(
1 meter from surface
)
<40dBA
(
1 meter from surface
)
Features
- AVR (Automatic Voltage Regulation)
- Fully Digitized Microprocessor Controlled
- Protects up to 4 Devices at Once
- Energy Saving Function (UPS Green Mode)
- 50/60Hz Frequency Auto Sensing and Selection
- USB Communication Port
- Advanced Battery Management (ABM Technology)
Includes
UPS Monitoring
Software
1-800-830-0051
www.ultraproducts.com