Special Features
Storing Frequencies Found During Direct
Entry Search into Channel Memory
Follow these steps to store frequencies received
during direct entry search mode or direct entry
search hold mode.
1. Press Func + Pgm in direct entry search mode
or direct entry search hold mode. The frequency
and lowest blank channel alternate on the
display.
2. Press E to store the frequency into the blank
channel. To select another channel, repeatedly
press Func + or Func + to select the blank
channel you want, then press E. You can also
use the 0-9 keys to select the bank.
If you enter a frequency that has already been
entered elsewhere, the scanner sounds an error
tone and displays the channel that was duplicated. If
you entered the frequency by mistake, press .
To enter the frequency anyway, press E to accept.
The scanner moves to program mode after you
stored the frequency.
Search Skip Memory
You can skip up to 50 specified frequencies during a
search. This lets you avoid unwanted frequencies or
those already stored in a channel.
Note: Search skip frequencies are shared by service
search, direct entry search, chain search, and Close
Call modes. If skip frequencies are sent in certain
mode, the frequencies are also skipped in other
search modes and Close Call mode.
To skip a frequency, press Func and L/O when the
scanner stops on the frequency during a search or a
search hold. The scanner stores the frequency in
UBC73XLT Paper OM.fm Page 42 Monday, May 14, 2007 9:13 AM