Page 45
USING AN ALTERNATE MOUNT OR STAND
If you will be using the DTF-521 in an installation that requires the use of an alternate mounting
platform, you can remove the adjustable stand from the unit and mount the pen display onto any mount
arm or stand conforming to the VESA 75 mm standard.
Mounting screws that are 4 mm wide with a 0.7 mm pitch (M4 Regular), with a screw clearance depth of
15 mm are required. Exceeding the clearance depth of 15 mm will damage the pen display internal
components.
To remove the adjustable stand and attach
the pen display to a different mounting
platform:
1. Turn off your computer and power off
the DTF-521. Then disconnect all
cables from between the unit and your
computer.
2. Protect the display screen surface by
spreading a soft cloth onto a flat table
and placing the DTF-521 face down on
the cloth.
3. Remove the four screws and lift the
adjustable stand assembly away from
the body of the unit.
4. Using the appropriate screws for your
mounting platform, firmly attach the
DTF-521 to the alternate mounting
platform.
5. Refer to the Installation instructions,
beginning on page 10, and reattach the
cabling.
CAUTION
When attaching the DTF-521 onto an alternate
mounting platform, be sure to follow all instructions in
the documentation supplied by the platform
manufacturer. If improperly installed, the unit could fall,
resulting in damage to the unit or physical injury.
DTF521_Manual.fm Page 45 Thursday, October 25, 2007 3:46 PM