Waterpik Technologies RS485 Printer User Manual


 
Phone Cable
from Wall Jack.
AquaLink RS
TeleLink Board
To RS485
4-Conductor
Cable
(Cable between
Controller and
Power Center)
2
Pro
g
ram
# of rin
g
s
(default: 4)
Pro
g
ram
access code
(default: 62)
®
red
black
yellow
green
1
Caution
Do not mount the TeleLink PCB in the
AquaLink Power Center. Keep in original
TeleLink enclosure.
!
The TeleLink enclosure will need to be installed as close as possible to a phone jack to keep the phone cord as
short as possible between the phone and the TeleLink. The TeleLink will need the phone cord to communicate with
the house phone. Run the 4-conductor wire from the TeleLink either to the AquaLink Power Center (connect to the
red 4-pin terminal bar) or the AquaLink indoor controller (connect to the red 4-pin terminal bar, the wires may be
doubled-up on the terminal bar). If running the 4-conductor wire to the AquaLink RS Power Center, use a strain
relief on one of the knockouts on the bottom of the Power Center.
NOTE: If you are installing more than one accessory board, order and use a Jandy Multiplex PCB Kit,
(p/n 6584). Never put more than two wires into each of the pins of the red terminal bar. Use the Multiplex PCB
whenever more than two of the 4-conductor wire are being connected.
AquaLink
®
RS TeleLink Telephone Interface
Installation Instructions- Jandy part #6590
6000 Condor Drive, Moorpark, CA, USA 93021 • 707.776.8200 FAX 707.763.7785
480 S. Service Road West, Oakville, Ontario, Canada L6K 2H4 • 905.844.8233 FAX 905.844.2635
Litho in U.S.A. © Water Pik Technologies, Inc. 2001
Sheet # 6862 Rev. E, 1/01 For Technical Support call 707-776-8200, ext. 260