Troubleshooting 181
Description: One or more physical drives were moved, causing a configuration
that is not supported.
Action: Move all drives to their original locations, and then refer to the server
documentation for supported configurations.
Swapped Cables or Configuration Error Detected. The Cables Appear To Be
Interchanged...
...SOLUTION: Power down system then move the drives or cables back to their original
location.
Description: ADU has detected a change in the cable configuration. One or more
cables may be connected to the incorrect bus or one or more drives have been
moved to new locations.
Action:
1. Refer to the server documentation for supported configurations and cabling
guidelines.
2. Restore to the original configuration.
Swapped Cables or Configuration Error Detected. The Configuration Information
on the Attached Drives...
...is not backward compatible with this controller’s firmware.
SOLUTION: Upgrade the firmware on this controller. If this doesn’t solve the problem
then power down system then move drives back to the original controller.
Description: The current firmware version on the controller cannot interpret the
configuration information on the connected drives.
Action: Upgrade the firmware.
-Or-
If the problem persists, move the drives to the original controller.