208 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide
601-Diskette Controller Error
Audible Beeps: None
Possible Cause: Diskette controller circuitry failure occurred.
Action:
1. Be sure the diskette drive cables are connected.
2. Replace the diskette drive, the cable, or both.
3. Run Insight Diagnostics ("HP Insight Diagnostics" on page 80
) and replace
failed components as indicated.
602-Diskette Boot Record Error
Audible Beeps: None
Possible Cause: The boot sector on the boot disk is corrupt.
Action:
1. Remove the diskette from the diskette drive.
2. Replace the diskette in the drive.
3. Reformat the diskette.
605-Diskette Drive Type Error.
Audible Beeps: 2 short
Possible Cause: Mismatch in drive type occurred.
Action: Run the server setup utility to set the diskette drive type correctly.