37
Reattach the drive cap assembly and the piston(s) and the
drive assembly.
the electronics and establishes the service piston posi-
position.
Injector Cap, Screen, Injector Plug and Injector Re-
placement
-
Rell Flow Control Assembly or Rell Port Plug
elbow-locking clip and then pull straight up on the elbow.
Replace the elbow locking clip in the slot so that it is not
-
screwdriver.
pushing the retainer into the elbow until the o-ring seats.
Remove locking clip, push down on elbow to reseat and
insert locking clip.
Do not use Vaseline, oils, or other unacceptable lubricants
on o-rings. A silicone lubricant may be used on the o-ring
on the elbow or the white retainer.
Water Meter or Meter Plug
The water meter assembly is connected to the PC board
replaced, remove the control valve cover and disconnect
assembly and through the drive back plate. To reinstall,
rethread the water meter through the drive back plate and
and the water meter and power plugs.
and cleaned. To remove the water meter assembly, un-
screw the meter cap. Pliers may be used to unscrew the
-
tween the valve body and the meter. When the meter is
Do not use a wire brush to clean the turbine. Wipe with
or vinegar. The turbine can be immersed in the chemical.
damaged or the bearings on the turbine are worn, replace
the turbine.
-
ings are prelubricated. Do not use Vaseline, oils, or other
unacceptable lubricants on the o-ring. A silicone lubricant
may be used on the black o-ring.
into the slot. Hand tighten the nut. Do not use a pipe
wrench to tighten nut.