3Com 3646A Power Supply User Manual


 
3600 Series Programmable Power Supply
VERSION 2.0 2004.6
12
3600 SERIES USER MANUAL
2.3.5 Recall parameters
In the last paragraph, we know that we can store 10 sets of parameters. Also you can recall
any one of them. It means that you needn’t to set up again for the usually requirements and it
brings you much conveninent. Users can recall one set of the data from the stored data sets.
Which including set up of 1)Voltage value; 2)Current value; 3)Maximum voltage; 4)Locked/
unlocked keypad; 5)Maximum power; 6)Baudrate; 7)Communication address.
The recall operation is as follows:
2.3.6 The function of the Menu
3600 series power supply provides a Menu operation for some special functions. The opera-
tion and functions are as follows:
Procedure The operation Methods LCD display
Step 1 Press “Recall” button CALL 1
Step 2 Enter the password ( Or jump to step 4 if the keyboard ENTER PASSWORD
is unlocked)
Step 3 Press “Enter” button ( it will return to step 2 if your ENTER PASSWORD
password is wrong for reentering) 1234
Step 4 Enter the number of the set data which you want to recall CALL 1
(from 1 to 10) by using the number key or rotate the
rotary knob to change the number
Step 5 Press “Recall” button to confirm , if the number is out of CALL *
the range from 1 to 10, it will retune to Step 2 for reenter
It will exit the Recall operation at any procedure by press ESC button