3Com MIC-3365 Modem User Manual


 
10 3COM IMPACT ISDN EXTERNAL DIGITAL MODEM QUICK START INSTRUCTIONS
9 If you have a second telephone number associated with
your ISDN telephone line (some telephone companies
require two), enter the number and corresponding SPID in
the appropriate fields in the Number 2 area.
10 Specify which device should receive the calls coming to
Telephone Number 2.
11 Click the Configure button to download the parameters
listed in steps 5 through 10 to your digital modem’s
S registers.
12 If you have changed the Telephone Company Switch type,
you must reset the digital modem by turning the power
switch off and then on.
13 Verify the configuration.
Check the status bar (located beneath the Help, Tools,
Configure, and Exit buttons of the Configuration dialog box)
to verify correct configuration. If the parameters were
configured accurately and the digital modem is ready to
send and receive calls, the status bar fields will appear as
shown below. Note that the TEI number(s) are not configured
by the user. The TEI number is provided by the telephone
company for informational purposes only.
Layer 1: UP
SPID 1: Init
TEI 1: Number from 0 to 127
SPID 2: Init (if required)
TEI 2: Number from 0 to 127 (if required)
14 Click Exit to leave the utility.
This completes the configuration procedure.
15 Install the TurboCom software.
Refer to the installation instructions that came with the
TurboCom software.
,
09-0700-002 Page 10 Sunday, December 22, 1996 3:40 PM