3M MP8760 Projector User Manual


 
3M IPC 2000 3M
Multimedia Projector MP8760 17
ENGLISH
Section 6: Maintenance
6-1. Replacing The Air Filter
For best performance, replace the air filter each time the projection lamp is changed.
!!
!!
Note
Periodically check air filter for excess dust or dirt.
Replace or clean as needed.
1. Unplug the power cord (1) of the projector.
2. Unscrew two screws
(2) securing back panel.
3. Remove the back panel
(3).
4. Separate the air filter from the back panel
(4).
5. Vacuum (5) the air filter to remove the dust and dirt.
6. Insert the air filter in the back panel.
7. Insert the back panel and secure with screws
(2).
Figure 6-1. Removing Air Filter Door
EPS-53A
AUX SVHS / AUDIO IN VIDEO 1 / AUDIO IN VIDEO 2 / AUDIO IN MONITOR
RS232
PC / RGB 2
PC / RGB 1
AUDIO IN AUDIO OUT
OI
5
2
1
3
2
4
6