Accton Technology 1000BASE-SX Gigabit Uplink Module Network Hardware User Manual


 
Troubleshooting
5
Maximum Cable Length
Troubleshooting
If you experience any problems with the module, check the following items before
contacting Accton Technical Support:
Ensure the switch with the fiber optic module is powered up.
Ensure that the device attached to the module is powered up and operating correctly.
Ensure that the module is properly seated in the slot.
Verify that the module port is configured to match the communication mode used
by the attached device (full or half duplex).
Check the connectors on both ends of the cable to be sure they are properly
engaged. When attaching fiber cable to an SC-type port, be sure the plug clicks
into place to ensure that it is properly seated.
If you are using fiber optic cable with an ST-type connector (in conjunction with the
SC-ST converter*), try switching the TX and RX connectors.
Be sure the fiber terminators are clean. You can clean the cable plugs by wiping
them gently with a clean tissue or cotton ball moistened with a little ethanol. Dirty
fiber terminators on fiber optic cables will impair the quality of the light transmitted
through the cable.
* You may use the Cheetah ST Converter (Part Number: ST5002) to attach 62.5/
125 micron fiber cable with an ST-type connector to the SC-type port on the fiber
optic module.
Cable Types and Specifications
Cable Type Max. Length
Connector
10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft)
RJ-45
100BASE-TX Cat. 5 100-ohm UTP 100 m (328 ft)
RJ-45
100BASE-FX 50/125 or 62.5/125 micron core multimode fiber
Half duplex 412 m (1,351 ft.)
SC or ST
Full duplex 2 km (1.24 miles)
SC or ST
1000BASE-SX 50/125 or 62.5/125 micron core
multimode fiber
See the following
table
SC or ST
Maximum Gigabit Ethernet Cable Length
Fiber Size Fiber Bandwidth Maximum Cable Length
62.5/125 micron 160 MHz/km 7-722 ft (2-220 m)
200 MHz/km 7-902 ft (2-275 m)
50/125 micron 400 MHz/km 7-1641 ft (2-500 m)
500 MHz/km 7-1805 ft (2-550 m)