28 Chapter 1
Nominal voltages (Vrms) 90 - 264
Inrush current The maximum inrush current will be less than 50A and 100A when the adapter
is connected to 100Vac(60Hz) and 240Vac(50Hz) respectively.
Efficiency High efficiency 85% minimum, at 100~240Vac AC input, full load, warm-up
condition.
Output Ratings (CV mode)
DC output voltage Offers constant voltage 19.0V output source with 150W max output power
capacity.
Noise + Ripple 300mvp-pmax (20MHz bandwidth) for resistor load
Output current 0 A (min.) 3.5A (max.)
Output Ratings (CC mode)
DC output voltage 18.0 ~ 20.0
Constant output 7.9A
Dynamic Output Characteristics
Start-up time 3 sec. (@115 Vac and 230Vac full load)
Hold up time 5ms min. (@115 Vac input, full load)
Over Voltage Protection (OVP) 25V
Short circuit protection Output can be shorted without damage, and auto recovery
Electrostatic discharge (ESD) 15kV (at air discharge)
8kV (at contact discharge)
Dielectric Withstand Voltage
Primary to secondary 4242 Vdc for 1 second-
Leakage current 60uA at 240Vac/60Hz
Regulatory Requirements 1. FCC class B requirements (USA)
2. VDE class B requirements (German)
3. VCCI classII requirements (Japan)
Power Management
ACPI Mode Power Management
Mech. Off (G3) All devices in the system are turned off completely.
Soft Off (G2/S5) OS initiated shutdown. All devices in the system are turned off completely.
Working (G0/S0) Individual devices such as the CPU and hard disk may be power managed in
this state.
Sleeping State (S3) CPU Power Down
VGA Power Down
PCMCIA Suspend
Audio Power Down
Hard Disk Power Down
Super I/O Power Down
Sleeping State (S4) Also called Hibernate state. System saves all system states and data onto the
disk prior to power off the whole system.
Dimensions and Weight
Item Details
Deminsions 330(W) x 240(D) x 23/31.3(H) mm (12.9 x 9.45 x 10.91/1.23 inches)
Weight 1.9Kg (4.23 lbs)
AC Adapter