Acer 5000 Laptop User Manual


 
Chapter 1 29
Regulatory Requirements Safety Requirements:
1.The subject product rated 100-120V 60Hz must be listed under UL 1950 and
certified with SCA Standard C22.2 No.950.
2.The subject product rated 200-240V 50Hz must comply with low voltage
directive 73/23EEC.
EMI Requirements:
1.The subject product rated 100-120V 60Hz must meet the EMI requirements
of FCC part 15, Subpart B for Class B Digital Device and get FCC Certification
before marketing into USA and Canada.
2.The subject product rated 200-240V 50Hz must meet the EMC Directive 89/
336/EEC.
3.The subject product rated 100-120V must meet the VCCI-2 EMI
requirements.
Power Management
Power Saving Mode Phenomenon
Standby Mode
Enter Standby Mode when
1.Standby/Hibernation hot-key is pressed
and system is not ready to enter Hibernation
mode.
2.System standby/ Hibernation timer expires
and system is not ready to enter Hibernation
mode.
T The buzzer beeps
T The Sleep indicator lights up
Hibernation Mode
Enter Hibernation Mode (suspend to HDD)
when
1.Hibernation hot-key is pressed and
system is ready to enter Hibernation mode
2.System Hibernation timer expires and
system is ready to enter Hibernation mode.
T All power shuts off
Display Standby Mode
Keyboard, built-in touchpad, and an external
PS/2 pointing device are idle for a specified
period.
T The display shuts off
Hard Disk Standby Mode
Hard disk is idle within a specified period of
time.
T Hard disk drive is in standby mode.
(spindle turned-off)
Environmental Requirements
Item Specification
Temperature
Operating
+0~+35
°C
Non-operating
-20~+65
°C
Package storage
-20~+65 °C
Humidity
Operating 10% to 90% RH, non-condensing
Non-operating 10% to 90% RH, non-condensing (Unpacked)
Non-operating 10% to 90% RH, non-condensing (Storage package)
Vibration
AC Adapter
Item Specification