Acer AT350 Server User Manual


 
5
Acer AT350 F1 Specifications
Technical Specifications
Dimensions
(with bezel)
434 (W) x 648 (D) x 178 (H) mm (17.2 x 25.5 x 7 inches)
Form factor
4U tower, rack mountable
System inlet
temperature
Operating 10° - 35° C (50° - 95° F) at sea level with an altitude
derating of 1° C per 305 m (1.8° F per 1000 ft.) above
sea level to a maximum of 3050 m (10,000 ft.) no direct
sustained sunlight. Maximum rate of change is 10°C/hr.
(18°F/hr.). The upper limit depends on the type and
number of options installed. System performance may
be reduced if operating with a fan fault or above 30°C
(86°F).
Non-operating -40° - 70° C (-40° - 158° F) Maximum rate of change is
20°C/hr. (36°F/hr.).
Relative humidity
(non-condensing)
Operating 8 - 90 % relative humidity (Rh), 28° C (82.4° F)
maximum wet bulb temperature, non-condensing
Non-operating 5 - 95 % relative humidity (Rh), 38.7° C (101.7° F)
maximum wet bulb temperature, non-condensing
Emissions
classification
(EMC)
FCC rating
Class A
Normative standards
EN55022, EN 61000-3-2, EN 61000-3-3, CISPR 22
Class A
Power supply Rated Steady –state power 720 W
Maximum Peak Power 728 W
BTU rating 2456.64 BTU/hr. at 100 - 240 VAC