Acer AT350 F2 Server User Manual


 
14
Acer AT350 F2 specifications
Power specifications
Redundant 920W Power Supply
Operational
Input Voltage
Range (Vrms)
100 to 240
Frequency
Range
(Nominal) (Hz)
60/50
Nominal Input
Voltage (Vrms)
100
120
200
208
220
230
240
Max. Rated
Output Wattage
920.28
920.16
919.24
918.88
918.54
918.50
918.22
Nominal Input
Current (A rms)
10.420
8.530
5.090
4.900
4.630
4.430
4.250
Max. Rated
Input Wattage
Rating (Watts)
1039.92
1021.55
1009.86
1010.03
1007.40
1005.65
1004.70
Max. Rated VA
(Volt-Amp)
1042.0
1023.6
1018.0
1019.2
1018.6
1018.9
1020.0
Efficiency (%) at
Max. Rated
Output Wattage
88.50
90.07
91.03
90.98
91.18
91.33
91.39
Power Factor
0.998
0.998
0.992
0.991
0.989
0.987
0.985
Leakage Current
(mA)
1.27
1.27
1.27
1.27
1.27
1.27
1.27
Max. Inrush
Current (A peak)
17.31
18.52
15.50
16.28
16.02
16.17
18.34
Max. Inrush
Current Duration
(mS)
4.51
4.42
4.34
4.32
4.31
4.29
4.27
Max. British
Thermal Unit
Rating (BTU/hr)
3140.929
3140.516
3137.380
3136.124
3134.974
3134.847
3133.892