Adams MDW-250L Postal Equipment User Manual


 
© Adam Equipment Company 2012 Page 15 Rev C5, January 2012
9.0 Error Messages
1.
0
00
0¯ ¯ ¯ ¯ ¯ Zero point is over the setting range
2.
0
00
0_ _ _ _ _ Zero is below the setting range
3.
Ad
AdAd
Ad¯ ¯ ¯¯ ADC is over max. range;
4.
Ad
AdAd
Ad _ _ _ _ ADC is below min. range;
5.
EEP.Er
EEP.ErEEP.Er
EEP.Er There is an error in the EEPROM
6.
C
CC
CAL.Er
AL.ErAL.Er
AL.Er There is an error in calibration
7.
C
CC
CAP
APAP
AP.-- The capacity will be displayed
8.
Lo.bAt
Lo.bAtLo.bAt
Lo.bAt The battery voltage or input power is below 5.6V.
9.
FULL
FULLFULL
FULL The capacity has been exceeded by the person
on the scale.
10.0 WARNING
Do not dismantle the weighing machine without following the necessary
instructions.
Do not jump while standing on the platform. This may damage the sensor
inside.
Do not move the weighing machine violently and abruptly. It is
recommended to move and put down the weighing machine gently.
It is suggested to wipe the stains with soft cloth soaked with detergent and
to wipe later with soft cloth too. Do not use organic solutions and boiled
water to wipe the stains. Do not use water for cleaning.
Keep the weighing machine in a dry and clean environment. Do not
expose it outdoor or use it in locations near fire, under direct sunshine or
with high temperature.
When lifting the height meter, it is suggested to pull it straight along the
pipe without using excessive force.