Specifications
ELECTRICAL
Insertion Loss Better than -.5 dB, 100 KHz to 100 MHz
Better than -.8 dB, 100 MHz to 300 MHz
Return Loss: Better than -20 dB, 100 KHz to 300 MHz
Monitor Loading Effect: < .4 dB change in insertion loss to 300 MHz
Monitor Level: 21.5 ± 1.5 dB, 100 KHz to 300 MHz
Isolation: < -55 dB at 22.368 MHz
Cross Talk: < -55 dB at 22.368 MHz
Phase Delay < 4 nanoseconds to 300 MHz
Pulse Template: Conform to CCITT Recomm. G.703
MECHANICAL
Retention Force: 7 lbs. minimum
Retention Torque: 4" per lbs. minimum
ENVIRONMENTAL
Thermal Shock: -40ºC to +60ºC operating
-55ºC to +85ºC non-operating
Moisture Resistance: 0% to 95%