ADC LSZH Network Card User Manual


 
10/06 • 101456AE
Furcation Tubing
Fiber Optic Cable
Furcation Tubing
2
www.adc.com • +1-952-938-8080 • 1-800-366-3891
Environmental Characteristics:
Storage Temperature -55˚ to 85 ˚C (-67˚ to 185 ˚F)
Operating Temperature -40˚ to 85 ˚C (-40˚ to 185 ˚F)
Installation Temperature -40˚ to 85 ˚C (-40˚ to 185 ˚F)
Specifications
Mechanical Characteristics:
Test Procedure Units Results
Crush Resistance EIA-FOTP-41A N/cm 1200
Impact Resistance EIA-FOTP-25B # of impacts 500
Flexing (# of Cycles) EIA-FOTP-104A # of cycles 10,000
Maximum Pulling Load EIA-FOTP-33A N (lb) 2000 (112)
Maximum Operating Load EIA-FOTP-33A N (lb) 1000 (67)
Min. Bend Radius @ Max Load EIA-FOTP-33A 15 x Cable OD
Low Temperature Bend Test EIA-FOTP-37A C (F) Passed @ -40 (-40)
Furcation Tubing
Outer Jacket
Aramid Yarn Strength (Kevlar)
Optional Pull String
Inner Tubing