ADC Four-Pair Riser Cable Network Router User Manual


 
5/08•104976AE
CopperTen
®
Four-Pair Riser Cable
TrueNet
®
CopperTen
®
Four-Pair Riser Cable
3
www.adc.com +1-952-938-8080 1-800-366-3891
NOTE: The above listed discrete frequency electrical performance values are provided for engineering information
only. Actual compliance testing is based on swept frequency measurements. The spec values are based on
TIA/EIA 568-B.2-10 specifications.
FREQ
(MHz)
FITTED
IMPEDANCE
(Ohms)
INSERTION
LOSS
(dB/100m)
RETURN LOSS
(dB/100m)
Pair-Pair NEXT
(dB/100m)
PSNEXT
(dB/100m)
SPEC Max TIA Spec Min TIA Spec Min TIA Spec Min TIA Spec
1 100 ± 5 1.7 2.0 26.5 20.0 88.4 74.3 87.2 72.3
4 100 ± 3 3.4 3.7 31.1 23.0 82.8 65.3 80.0 63.3
8 100 ± 3 4.9 5.2 37.2 24.5 73.5 60.8 72.1 58.8
10 100 ± 3 5.5 5.9 30.3 25.0 73.9 59.3 71.7 57.3
16 100 ± 3 7.0 7.4 32.0 25.0 67.5 56.2 66.4 54.2
20 100 ± 3 7.8 8.3 35.2 25.0 70.0 54.8 68.5 52.8
25 100 ± 3 8.8 9.3 35.4 24.3 68.1 53.3 67.7 51.3
31.25 100 ± 3 9.9 10.4 38.9 23.6 67.4 51.9 64.7 49.9
62.5 100 ± 3 14.1 14.9 33.6 21.5 60.3 47.4 59.6 45.4
100 100 ± 3 18.0 19.0 28.1 20.1 59.2 44.3 57.8 42.3
155 100 ± 3 22.6 24.0 28.4 18.8 50.6 41.4 50.0 39.4
200 100 ± 3 25.8 27.5 27.3 18.0 52.5 39.8 51.4 37.8
250 100 ± 3 29.0 31.0 27.2 17.3 50.9 38.3 49.8 36.3
300 100 ± 3 31.8 34.2 25.0 16.8 46.9 37.1 46.4 35.1
350 100 ± 3 34.5 37.2 23.5 16.3 43.8 36.1 43.3 34.1
400 100 ± 3 37.0 40.0 24.5 15.9 47.2 35.3 44.7 33.3
450 100 ± 3 39.4 42.7 22.9 15.5 45.9 34.5 42.8 32.5
500 100 ± 3 41.6 45.3 21.3 15.2 48.2 33.8 47.0 31.8
550 100 ± 3 43.8 21.4 46.2 44.6
600 100 ± 3 45.9 21.2 44.2 43.0