![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/9/8b/98bdc741-ee64-413f-9a7f-f35cb20220b4/98bdc741-ee64-413f-9a7f-f35cb20220b4-bg2.png)
11/08 • 106805AE
WorldDSL
™
HDSL
WorldDSL
™
HDSL
Economical, Reliable, and Manageable E1 and Serial Data Deployment
2
www.adc.com • +1-952-938-8080 • 1-800-366-3891
Features
Fiber optic quality (BER 10•
-10
)
LTUs can provide line powering for up to two •
doublers for very long reach loops
LTUs can provide wetting current to reduce •
corrosion of connections
Point-to-multipoint configurations where a single •
central office card can operate two 1 Mbps
remote NTUs each via a single twisted pair to
reduce system costs
User software selectable dataport interface•
Single pair mode where the unit uses only one pair •
at a maximum rate of 1Mbps
Timeslot priority mode where, if one of the two •
HDSL pairs fails, the FAS, signaling and first 15 voice
channels are switched to the operating pair
0.91 mm0.40 mm 0.51 mm 0.64 mm
1
0
2
3
4
5
6
7
RANGE (KILOMETERS)
MAXIMUM
TYPICAL
MINIMUM
9
8
Wire Gauge (mm)
Figure 1
Single Span Reach
0.91 mm0.40 mm 0.51 mm 0.64 mm
4
2
6
8
10
12
14
16
RANGE (KILOMETERS)
MAXIMUM
TYPICAL
MINIMUM
20
18
Wire Gauge (mm)
Figure 3
3 Span Two Doublers Reach
0.91 mm0.40 mm 0.51 mm 0.64 mm
RANGE (KILOMETERS)
MAXIMUM
TYPICAL
MINIMUM
4
2
6
8
10
12
14
16
20
18
Wire Gauge (mm)
Figure 2
2 Span Single Doubler Reach
0.91 mm0.40 mm 0.51 mm 0.64 mm
1
0
2
3
4
5
6
7
RANGE (KILOMETERS)
MAXIMUM
TYPICAL
MINIMUM
9
8
Wire Gauge (mm)
Figure 1
Single Span Reach
0.91 mm0.40 mm 0.51 mm 0.64 mm
4
2
6
8
10
12
14
16
RANGE (KILOMETERS)
MAXIMUM
TYPICAL
MINIMUM
20
18
Wire Gauge (mm)
Figure 3
3 Span Two Doublers Reach
0.91 mm0.40 mm 0.51 mm 0.64 mm
RANGE (KILOMETERS)
MAXIMUM
TYPICAL
MINIMUM
4
2
6
8
10
12
14
16
20
18
Wire Gauge (mm)
Figure 2
2 Span Single Doubler Reach
0.91 mm0.40 mm 0.51 mm 0.64 mm
1
0
2
3
4
5
6
7
RANGE (KILOMETERS)
MAXIMUM
TYPICAL
MINIMUM
9
8
Wire Gauge (mm)
Figure 1
Single Span Reach
0.91 mm0.40 mm 0.51 mm 0.64 mm
4
2
6
8
10
12
14
16
RANGE (KILOMETERS)
MAXIMUM
TYPICAL
MINIMUM
20
18
Wire Gauge (mm)
Figure 3
3 Span Two Doublers Reach
0.91 mm0.40 mm 0.51 mm 0.64 mm
RANGE (KILOMETERS)
MAXIMUM
TYPICAL
MINIMUM
4
2
6
8
10
12
14
16
20
18
Wire Gauge (mm)
Figure 2
2 Span Single Doubler Reach
G.703
120/75Ω
Serial
V.35/V.36/RS-530/X.21
G.703
120/75Ω
Serial
V.35/V.36/RS-530/X.21
LTU or
UTU
UTU*
UTU**LTU
7.5 Km on 0.4 mm
12.5 Km on 0.64 mm
3.2 Km on 0.4 mm
5.3 Km on 0.64 mm
E1 (G.703)
120/75Ω
Serial
V.35/V.36/RS-530/X.21
E1 (G.703)
120/75Ω
Serial
V.35/V.36/RS-530/X.21
Typical Single Span Applications
Typical 3-Span Extended Reach with doublers line powered and remote UTU locally powered
EDU EDU
* Can be line powered from LTU or AC or DC local powered
** AC or DC local power required