ADC R4S Switch User Manual


 
2/08 • 105969AE
UltraWave R4S
3
www.adc.com +1-952-938-8080 1-800-366-3891
UltraWAVE R4S
Scalable MSC with Integrated Value Added Services
Specifications for MSS
Capacity
Call processing: 200,000 BHCA for SMS/LU
Traffic: 2,500 Erlang
VLR: 100,000 subscribers
HLR: 100,000 subscribers
Power supply: Optional dual-redundant 450W AC or DC hot-swap power supply
Physical: 1.70in.(4.32cm)x16.93in.(43cm)x20in.(50.8cm) (HxWxD)
Safety and EMC: UL 60950-1, 1st edition/CSA222, Low Voltage Directive 73/23/EEC,
TUV/GS to EN60950-1, 1st edition, CB Certificate and Report to IEC
60950-1 1st edition and all international deviations
EMC Directive 89/336/EEC
EN55022, EN55024, EN61000-4-x (where x is 2, 3, 4, 5, 6, 8 and 11)
EN61000-3-2, EN61000-3-3
FCC47 CFR parts 2 and 15 Verified Class A Limit
ENVIRONMENTAL
Temperature (operating): 41°F to 104°F (5°C to 40°C)
Temperature (non-operating): -104°F to 158°F (-40°C to 70°C)
RoHS Directive 2002/95/EC
(NEBS-3 compliant server available on request)
Specifications for Media Gateway
TDM interface: ISUP SS7, ISDN PRI
Capacity: 4 to 16 E1 ports per Media Gateway
(Larger Media Gateway available on request)
IP Network interface: Dual 10/100 Base-T Ethernet ports via 2 RJ-45 connectors
Power supply: Single universal 90-260VAC or dual-redundant AC or single -48VDC
Physical: 1U high, 19-inch wide rack mount
Safety and EMC: UL60950
FCC part 15 Class A
CE Mark (EN55022 Class A, EN60950, EN55024, EN300386)
ENVIRONMENTAL
NEBS Level 3: GR-63-Core (DC-powered model), GR-1089-Core Type 1 and 3, ETS300 019