SPEC SHEET
Website: www.adc.com
FromNorthAmerica,CallTollFree:1-800-366-3891•OutsideofNorthAmerica:+1-952-938-8080
Fax:+1-952-917-3237•ForalistingofADC’sglobalsalesofficelocations,pleaserefertoourwebsite.
ADCTelecommunications,Inc.,P.O.Box1101,Minneapolis,MinnesotaUSA55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may
verifyproductspecificationsbycontactingourheadquartersofficeinMinneapolis.ADCTelecommunications,Inc.
views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features
containedhereinmaybecoveredbyoneormoreU.S.orforeignpatents.AnEqualOpportunityEmployer
106823AE 8/08 Revision © 2008, 2005, 2004 ADC Telecommunications, Inc. All Rights Reserved
The Radiator II Below Ground HDSLx 8-Slot Repeater Housing is designed to withstand hostile
conditions, improve thermodynamic performance and reliability of the outside plant electronics in
50 percent less manhole space than traditional enclosures. It includes a 30-foot, 100-pair air core
screened, dual armor cable stub.
CENTRAL OFFICE
ELECTRONICS
CUSTOMER PREMISES
ELECTRONICS
OSP
Repeaters Repeaters
RADIATOR
OSP
RADIATOR
Specifications
Housing Construction, Lid: Non-corrosive 18-gauge seamless, 316 stainless steel, painted white
Capacity: Supports 8 single or a maximum of 6 double wide HDSL, HDSL4,
G.SHDSL, T1, ISDN and DDS repeaters
Ambient Temperature Range: –40˚Fto+149˚F(–40˚Cto+65˚C)
Relative Humidity: 100% when pressurized
Pressurization: 12 psi maximum – pressure relief valve
Security: V-band may be secured with a padlock
Dimensions: Diameter 12.5”, housing and mounting bracket together 14.25” high
Weight (without modules/cable stub): Approximately 28 lbs.
Mounting: Backboard or underground rack mount
Lightning Protection: Three-element gas tube
Safety Standards Compliance: Equipment tested and verified to comply with the following standards:
GR 63-CORE: Network Equipment-Building System (NEBS) Requirements
GR 487-CORE: Generic Requirements for Electronic Equipment Cabinets
GR 950-CORE: GenericRequirementsforOpticalNetworkUnit(ONU)Closures
TR-TSY-000056: Repeater Housings for T1, T1C, T1D, and T1G Carrier Systems
FCC Part 15: Electrical Safety
Binational Standard: UL-60950/CSA C22.2 No. 950-95: Safety of Information
Technology Equipment
Ordering Information
Description Catalog Number
Radiator II 8-Slot Below Ground HDSLx Repeater Housing
30’ air core stub, pressurized
RAD-BA30-8