ADTRAN 1442880G1 Switch User Manual


 
The ADTRAN system chassis frame ground
terminal must be connected to a reliable earth
ground to ensure that the metal enclosure of the
SFP is properly grounded via the backplane
connector.
NOTE: The 3.125 Gigabit Ethernet port(s) are optical and
therefore are not classified as any type of port as
defined in Appendix B of GR-1089-CORE Issue 4.
The SFP is designed to meet the following environmental
classes:
ETSI EN 300 019-1-1 “Classification of
environmental conditions; Storage,” Class 1.2
ETSI EN 300 019-1-2 “Classification of
environmental conditions, Transportation,” Class 2.3
ETSI EN 300 019-1-3 “Classification of
environmental conditions, Stationary use at weather-
protected locations,” Class 3.3
The equipment is designed to function without degra-
dation during exposure to all test severities per Class 3.3.
COMPLIANCE
CAUTION: Electrostatic Discharge (ESD) can damage
electronic modules. When handling modules,
wear an antistatic discharge wrist strap to
prevent damage to electronic components. Place
modules in antistatic packing material when
transporting or storing. When working on
modules, always place them on an approved
antistatic mat that is electrically grounded.
The SFP is a Class 1 Laser Product and complies
with the Laser Safety requirements of FDA
21CFR 1040.10 and 1040.11, and EN60825-1
and -2. The SFP is NRTL Listed and CB Certified
to all applicable American and European safety
standards.
The SFP meets or exceeds all the applicable
requirements of NEBS, Telcordia GR-63-CORE,
and GR-1089-CORE. The SFP is intended for
deployment in Central Office type facilities,
EEEs, EECs, and locations where the NEC
applies (for example, Customer Premises). The
SFP is to be installed in ADTRAN products in
Restricted Access Locations only, and installed
by trained service personnel.
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received,
including interference that may cause undesired
operation.
Changes or modifications not expressly approved by
ADTRAN could void the user's authority to operate this
equipment.
CAUTION: Per GR-1089-CORE the ADTRAN system that
the SFP is being deployed in is designed and
intended for installation as part of a Common
Bonding Network (CBN). The ADTRAN system
that the SFP is being deployed in is not designed
nor intended for installation as part of an
Isolated Bonding Network (IBN).
Per GR-1089-CORE Section 9, the SFP does not
have an internal DC connection between battery
return and frame ground. The SFP can be
installed in a DC-I (isolated) or DC-C (common)
installation. For installations where other cards
or the host system have internal connections
between battery return and frame ground, the
system would be intended for deployment only
in a DC-C installation.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet
its published specifications or fails while in service. Warranty information can be found
online at www.adtran.com/warranty
.
© 2008 ADTRAN, Inc. All Rights Reserved.
*61442880G1-22A*
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
CLEI: SOOTAKEJ_ _
Product P/N: 1442880G1
Issue Date: 0804
Document P/N: 61442880G1-22A
PRICING AND AVAILABILITY 800.827.0807
TECHNICAL SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
Small Form-Factor Pluggable
3.125 Gigabit Ethernet 80 km