Troubleshooting
If your NT1 ACE does not operate properly, please check
the lists of symptoms and solutions below. For further assis-
tance, please contact ADTRAN technical support at 888-
4ADTRAN.
POWER indicator does not illuminate.
Verify power connection.
Move power supply to another circuit.
Call ADTRAN technical support for assistance.
ERROR indicator illuminated; READY indicator flashes
at a faster 8 Hz rate.
Network activation failure:
Wall jack wiring is incorrect: Check wall jack.
Problem with ISDN line: Contact telephone com-
pany.
ERROR indicator illuminated; READY indicator flashes
at a slower 1 Hz rate.
Local bus failure:
TE not connected: Connect TE.
TE not receiving power from NT1: Consult TE doc-
umentation.
TE not terminated properly: Review the section
Setting the Option Switches on page 4.