Total Access 750/850/1500 OCU DP Access Module
OCU DP Pair Locator for Total Access 750/850/1500
PROVISIONING
The Total Access 750/850/1500 OCU DP supports two types of provisioning modes, local and remote.
Local provisioning results in the module operating as defined by the on-board switches. Remote
provisioning results in the module operating as defined by the Bank Controller Unit (BCU) or System
Controller Unit (SCU) menu settings (on-board switches are ignored). The operational mode is
indicated by the REM LED and can be changed by depressing the AP switch on the front panel.
Remote Provisioning
The craft interfaces on the BCU or SCU are used to change default options and obtain access module
status through menu screens. To access the menu screens, connect a VT100 terminal or a computer
running a terminal emulation program to the front panel craft interface ADMIN port using a standard
male-to-female RS-232 DB-9 cable.
Windows HyperTerminal can be used as a VT100 terminal emulation program. Open HyperTerminal
by selecting
Programs/Accessories/HyperTerminal. Refer to the Help section of HyperTerminal for
additional information.
To traverse through the menus, select the desired entry and press
ENTER. To work backward in the
menu press the
ESC (escape) key. The figure on the right illustrates the OCU DP menu tree.
TESTING
The OCU DP is equipped with logic level bantam test access jacks that permit testing in both directions
using a portable test set. Latching and alternating OCU and CSU loopback sequences are supported.
Alternating loopbacks do not operate when the 64 kbps data rate is selected. Choose NEAR to test
toward the 4-wire customer loop direction; choose FAR to test toward the T-carrier.
TA 1500
Slot
T/R
RX (P1)
T1/R1
TX (P2)
TA 1500
Slot
T/R
RX (P1)
T1/R1
TX (P2)
TA 750/
850 Slot
T/R
RX
T1/R1
TX
1 26/1 26/1 13 38/13 38/13 1 26/1 27/2
2 27/2 27/2 14 39/14 39/14 2 30/5 31/6
3 28/3 28/3 15 40/15 40/15 3 34/9 35/10
4 29/4 29/4 16 41/16 41/16 4 38/13 39/14
5 30/5 30/5 17 42/17 42/17 5 42/17 43/18
6 31/6 31/6 18 43/18 43/18 6 46/21 47/22
7 32/7 32/7 19 44/19 44/19
8 33/8 33/8 20 45/20 45/20
9 34/9 34/9 21 46/21 46/21
10 35/10 35/10 22 47/22 47/22
11 36/11 36/11 23 48/23 48/23
12 37/12 37/12 24 49/24 49/24
In the FAR direction, an OCU loopback sequence will loop the unit directly across the carrier system.
In the NEAR direction, an OCU loopback sequence will loop the unit directly connected to the portable
test set.
NOTE: If 64 kbps is selected, unit will only respond to latching loopback sequences. Alternating
sequences are not valid at this rate.
COMPLIANCE
The OCU DP is NRTL listed to the applicable UL standards. The OCU DP is to be installed in a
restricted access location and in a Type “B” or “E” enclosure only.
The Total Access 750/850/1500 Chassis frame ground terminal must be connected to an earth ground
to ensure the front panel of the OCU DP is properly grounded via the backplane connector.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired
operation.
Changes or modifications not expressly approved by ADTRAN could void the user’s authority to
operate this equipment.
Code Input Output
Power Code (PC) C C
Telecommunication Code (TC) X
Installation Code (IC) A
1. Configuration
2. Provisioning
3. Status
Unit Name
Part Number
CLEI Code
Software Revision
1. Disabled
2. Enabled
1. Data Rate
3. Latching Loopback
4. Quality Monitor Disconnect
5. Error Correction
6. Zero Code Suppression
7. Hardware A/B Signaling
2. Secondary Channel
1. 64 kpbs
2. 56 kbps
3. 19.2 kbps
4. 9.6 kbps
5. 4.8 kbps
6. 2.4 kbps
7. Sw56
1. Disabled
2. Enabled
1. Disabled
2. Enabled
1. Disabled
2. Enabled
1. Disabled
2. Enabled
1. Disabled
2. Enabled
ABS Code to Network
Loop Sealing Current
Loop Receive Signal
Quality Monitor Decision
Loop Circuit
Loopback