ADTRAN T200 T1 HDSL4 Network Card User Manual


 
6 61223441L1-5C
Installation T200 H4R Installation and Maintenance Practice
3. INSTALLATION
After unpacking the T200 H4R, inspect it for damage. If damage has occurred, file a claim with the carrier, then
contact ADTRAN Customer Service. Refer to “Appendix A, Warranty” for further information. If possible, keep
the original shipping container for returning the T200 H4R for repair or for verification of shipping damage.
There are no manual option settings for the H4R.
Shipping Contents
The contents include the following items:
T200 T1 HDSL4 Repeater
T200 T1 HDSL4 Repeater Job Aid
CAUTION
Electronic modules can be damaged by ESD. When handling modules, wear an
antistatic discharge wrist strap to prevent damage to electronic components. Place
modules in antistatic packing material when transporting or storing. When working
on modules, always place them on an approved antistatic mat that is electrically
grounded.
Installation Instructions
To install the T200 H4R, perform the following steps:
1. If present, remove the Access Module Blank from the appropriate slot of the enclosure.
2. Hold the T200 H4R by the front panel while supporting the bottom edge of the module.
3. Align the module edges to fit in the lower and upper guide grooves for the module slot.
4. Slide the module into the slot. Simultaneous thumb pressure at the top and at the bottom of the module will
ensure that the module is firmly seated against the backplane of the enclosure.
When the unit first powers up it runs the a series of self-tests. Once the power up self-test is complete the status
LEDs will reflect the true state of the hardware.
H4R power is derived from an H4TU-C, independent of line impedance or wire gauge. The operating power from
the H4TU-C may also be used to span power the H4TU-R.
The T200 H4R is designed for deployment in any Type 200 form factor enclosure.
When installing the ADTRAN T200 H4R refer to the Installation and Maintenance Practice for the housing being
used.
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.