Alcatel Carrier Internetworking Solutions TQBJ0223 Projector User Manual


 
44
Using Web Browser Control
Contents of mail sent
Mail with the contents shown below is sent when the E-mail
settings have been established.
Adjust clock page
Click [Network set up], then [Adjust clock] to display the Adjust clock page.
Mail with the contents shown below is sent
when an error has occurred.
If the time becomes incorrect immediately after setting the correct time, then the battery needs to
be changed. Contact the dealer where you bought the projector to have the battery changed.
Note
=== Panasonic projector report(CONFIGURE) ===
Projector Type : D4000
----- E-mail setup data -----
TEMPERATURE WARNING SETUP
MINIMUM TIME at [ 60] minutes interval
INPUT AIR TEMPERATURE Over [ 45C / 113F ]
ERROR [ ON ]
LAMP1 RUNTIME [ ON ] at REMAIN [ 100] H
LAMP1 RUNTIME [ ON ] at REMAIN [ 200] H
LAMP2 RUNTIME [ ON ] at REMAIN [ 300] H
LAMP2 RUNTIME [ ON ] at REMAIN [ 400] H
INPUT AIR TEMPERATURE [ OFF ]
PERIODIC REPORT
Sunday [ ON ] Monday [ OFF ] Tuesday [ ON ] Wednesday [ OFF ]
Thursday [ ON ] Friday [ OFF ] Saturday [ ON ]
00:00 [ ON ] 01:00 [ OFF ] 02:00 [ ON ] 03:00 [ OFF ]
04:00 [ OFF ] 05:00 [ ON ] 06:00 [ OFF ] 07:00 [ ON ]
08:00 [ ON ] 09:00 [ OFF ] 10:00 [ ON ] 11:00 [ OFF ]
12:00 [ OFF ] 13:00 [ ON ] 14:00 [ OFF ] 15:00 [ ON ]
16:00 [ ON ] 17:00 [ OFF ] 18:00 [ ON ] 19:00 [ OFF ]
20:00 [ OFF ] 21:00 [ ON ] 22:00 [ OFF ] 23:00 [ ON ]
----- check system -----
MAIN CPU BUS [ OK ]
FAN [ OK ]
OPTICS MODULE TEMPERATURE [ OK ]
INPUT AIR TEMPERATURE [ OK ]
AROUND LAMP TEMPERATURE [ OK ]
LAMP2 REMAIN TIME [ OK ]
LAMP1 REMAIN TIME [ OK ]
=== Panasonic projector report(ERROR) ===
Projector Type : D4000
––––– check system –––––
MAIN CPU BUS [ OK ]
FAN [ OK ]
OPTICS MODULE TEMPERATURE [ OK ]
INPUT AIR TEMPERATURE [ OK ]
AROUND LAMP TEMPERATURE [ OK ]
LAMP2 REMAIN TIME [ OK ]
LAMP1 REMAIN TIME [ OK ]
LAMP2 STATUS [ OK ]
LAMP1 STATUS [ OK ]
SHUTTER [ FAILED ]
AIR FILTER [ OK ]
OPTICS MODULE TEMP.SENSOR [ OK ]
INPUT AIR TEMP.SENSOR [ OK ]
AROUND LAMP TEMP.SENSOR [ OK ]
BATTERY [ OK ]
AIRFLOW SENSOR [ OK ]
COLOR WHEEL [ OK ]
COVER OPEN [ OK ]
(Error code 00 10 00 00 00 00 00 00)
Input air temperature : 30 degC / 86 degF
Optics module temperature : 30 degC / 86 degF
Around lamp temperature : 37 degC / 98 degF
SET RUNTIME 30 H
POWER ON 33 times
LAMP1 ON 34 times
LAMP1 HIGH 5 H
LAMP2 ON 24 times
LAMP2 HIGH 4 H
LAMP1 REMAIN 1476 H
LAMP2 REMAIN 1484 H
----- Network configuration -----
IP address 192.168.0.8
MAC address 00:00:00:00:00:00
Thu Mar 02 14:11:02 2006
----- Memo -----
Time zone selection
Button to update time zone setting
Button to update time and date
settings
New date field
New time field