Alcatel-Lucent 1850 TSS-320 Switch User Manual


 
Alcatel-Lucent 1850 TSS-320 | Release 3 | Data Sheet 3
Protection
•Ethernetnetworkprotection
¬RSTP:802.1w
¬MSTP:802.1s
¬ Link aggregation
•T-MPLSnetworkprotection
¬TunnelLinearProtection1:1
•SONET/SDHnetworkprotection
¬Single-anddual-endedAPS1+1
¬ Subnetwork Connection Protocol
(SNCP), unidirectional path-
switchedring(UPSR)
¬ Multiplex Section-Protection Ring
(MSPRING)2Fbidirectionalline
switchingring(BLSR)
•Equipmentprotection
¬ Power protection
¬ Controller protection
¬Universalswitchprotection
GMPLS control plane
•T-MPLStunnelsetup
•TDMHOpathsetup
Management
•Alcatel-Lucent1350Optical
Management System (OMS)
• TL1
•Zero-installation
craft(ZIC)terminal
•SimpleNetworkManagement
Protocol (SNMP)
•Commandlineinterface(CLI)
•SecureShell(SSH)v2/SecureSocket
Layer (SSL) for secure connection
Physical specifications
ANSI
Dimensions: 1850 TSS-320 subrack
•Subrackdimensions
¬Height:624mm(24.6in.)
¬Width:532mm(20.9in.)
¬Depth:304.8mm(12.0in.)/
355.6 mm (14.0 in.)
•Designedtobeinstalledin
a standard ANSI rack
¬Height:2.13m(7ft)
¬Width:660.4mm(26.0in.)
¬Depth:304.8mm(12.0in.)/
355.6 mm (14.0 in.)
Power and cooling
•Powersupply:DCfeed(-48VDC
nominal)
•Powersupply:-58V
•Powerconsumption:upto3500W
•Cooling:forcedair
Environmental
•Operatingtemperature:
-5°Cto+45°C(23°Fto113°F)
•Relativehumidity:
0% to 90%, non-condensed
Regulatory compliance
•CEandULcertification
•NEBSlevel3
•FCCpart15classA
ETSI
Dimensions: 1850 TSS-320 subrack
•Subrackdimensions
¬Height:624mm(24.6in.)
¬Width:532mm(20.9in.)
¬Depth:288mm(11.3in.)
•Designedtobeinstalledin
a standard ETSI rack
¬Height:2.20m(86.6in.)
¬Width:600mm(23.6in.)
¬Depth:300mm(11.8in.)
Power and cooling
•Powersupply:DCfeed
(-48 V DC nominal)
•Powersupply:-65V
•Powerconsumption:upto3500W
•Cooling:forcedair
Environment
•Operatingtemperature:
-5°Cto+45°C(23°Fto113°F)
•Relativehumidity:0%to90%,
non-condensed
Regulatory compliance
•CEcertification
•Operatingconditions:
ETS 300 019, Class 3.2
•Storageconditions:
ETS 300 019, Class 1.2
•Transportationconditions:
ETS 300 019, Class 2.2
•Electrostaticdischarge(ESD)/
electromagnetic compatibility
(EMC):ETS300386“Telecommuni-
cations Center”