Alcatel-Lucent 7250 SAS Switch User Manual


 
Alcatel-Lucent 7250 SAS | Data Sheet 4
•Pseudo-wirestatus-notification
messageaccordingtoRFC4447
•LocalloopbackforTDMport
•LocalloopbackforCESservice
•Biterror-ratetestonthelocal
TDMport
Physical interfaces
• 10/100Base-T:
¬Connectors:RJ-45
¬Transmission:Full/halfduplex
¬Range:100m(328.08ft)
¬Ports:Auto-sensing
•100Base-FX:SFP-based,LC
connector
•1000Base-X:SFP-based,LC
connector
•4-portDS1/E1module:E1/T1
toRJ-48cconnector
•4drycontactinputsthrough
aDB-9connector
Dimensions
•Height:44mm(1.73in.)
•Width:440mm(17.32in.)
•Depth:419mm(16.5in.)
Weight
•Chassiswithoutpowersupply
unit(PSU):3.7kg(8.2lb)
•SingleACpowersupply:0.6kg
(1.3lb)
•SingleDCpowersupply:0.6kg
(1.3lb)
Power supply
•Redundant,hot-swappable
• ACversion:100Vto240V,
50/60Hz
•DC(-48V)version:-36Vto-75V
•Powerconsumption:90W
maximum
Certification
•Safety:EN60950-1(2001),
AS/NZS60950.1(2003)
•EMC
¬EmissionsEN55022-1998/A1-
2000/A2-2003
¬ICES-003Issue4ClassA
¬FCC47CFRPart15ClassA
¬VCCIClassA
¬AS/NZSCISPR22-2002ClassA
¬EN61000-3-2-2000
¬EN61000-3-3-1995/A1-2001
•Immunity
¬EN55024-1998/A1-2001/A2-
2003
•EmissionsandImmunity
¬EN300386v1.3.2
•NetworkEquipmentBuilding
System(NEBS)Level3compliant
•CESModuleandHighPerformance
CESModule
¬AS/ACIFS016-2001
¬FCCPart68;TIA-968-A/A1,A2,
A3;IndustryCanada,IC-CS03
¬TBR12-1993/A1-1996
Environment
•Operatingtemperature:0ºCto
45ºC(32ºFto113ºF)
•Short-termextendedtemperature:
-20ºCto+60C(-4ºFto+140ºF)
•Humidity:Upto95%,non-
condensing
Network management
•The7250SASissupportedby
the5620SAM,including:
¬5620SAM-E
¬5620SAM-P
¬5620SAM-A
•Standardmanagementsupport
includes:
¬STD-15
¬SNMPv1
¬STD-16SMIv1
¬STD-17MIB-11
¬STD-50EtherLikeMIB
¬STD-58SMIv2
¬STD-59RMON
¬STD-62SNMPv3
¬SNMPv2c
¬SNMPv1
¬RFC2668MAU
¬RFC29250
¬PingMIB
•Commandlineinterface(CLI)
¬Serial
¬Telnet
¬SecureShell(SSH)
•Interface:In-band/out-of-band
•Localinterface:RJ-45,TIA/
EIA-232
•Softwaredownload:TrivialFile
TransferProtocol(TFTP)
•RemoteAuthenticationDial-In
UserService(RADIUS)
•Syslog
Standards compliance
IEEE standards
•IEEE802.1dSpanningTree
Algorithm
•IEEE802.1pPriorityQueuing
•IEEE802.1qVLANTagging
•IEEE802.1wRapidSpanningTree
•IEEE802.1sMultipleSpanning
Tree
•IEEE802.1adProviderEdgeBridges
•IEEE802.1agConnectivityFault
Management
•IEEE802.3adLinkAggregation
•IEEE802.3EthernetCSMA/CD
AccessMethodandPhysicalLayer
Specifications
•IEEE802.3ahEthernetFirstMile
•IEEE802.3uFastEthernet
• IEEE802.3xFlowControlonAccess
•IEEE802.3zGigabitEthernet
IETF specifications
General
•RFC768UserDatagramProtocol
•RFC783TFTP
•RFC791InternetProtocol
•RFC792InternetControlMessage
Protocol
•RFC793TransmissionControl
Protocol
•RFC826EthernetAddress
ResolutionProtocol
•RFC854TelnetProtocol
Specification
•RFC1122RequirementsforInter-
netHosts-CommunicationLayers
•RFC1518ClasslessInter-Domain
Routing(CIDR)Architecture
•RFC1519ClasslessInter-Domain
Routing(CIDR)
•RFC1812RequirementsforIPv4
RoutersDiffServ
•RFC2474DefinitionoftheDiffer-
entiatedServicesField(DSField)
inIPv4andIPv6Headers
•RFC2475DiffServCoreandEdge
RoutingFunctions
•RFC2597DiffServeAssured
Forwarding
•RFC3140PerHopBehavior
IdentificationCodes
•RFC3246/2598ExpeditedFor-
wardingPHB
Table 1. 7250 SAS platform variant requirements for key features
KEY FEATURE 7250 SAS* (3HE01188AA) 7250 SAS ES (3HE01189AA) 7250 SAS ESA (3HE03250AA)
Ethernetswitchingandbridging √ √
CES √ √
EnhancedGigEuplink(withH-QoS, √
MPLS,FRR,RSVP-TE)
Drycontactinputs,loose-hopLSPs,
dynamicbypassLSPs,5620SAMsupport
forServerAssignmentAnswer(SAA),
pseudo-wirestatusmessage
* Note: A 7250 SAS standard-variant manufacturer-discontinuation notification was issued in October 2007.