Alcatel-Lucent 7670 RSP Switch User Manual


 
Physical Dimensions
Peripheral shelf
> Height: 93.3 cm (36.7 in.)
>
Width: 54.5 cm (21.4 in.)
> Depth: 54.5 cm (21.4 in.) without
cables; 60 cm (23.6 in.) with cables
Switching shelf
>
Height: 97.7 cm (38.4 in.)
> Width: 54.5 cm (21.4 in.)
> Depth: 54.5 cm (21.4 in.) without
cables; 60 cm (23.6 in.) with cables
Edge services extender shelf
> Height: 92.0 cm (36.7 in.)
> Width: 44.0 cm (17.3 in.)
> Depth: 31.0 cm (12.2 in.) without
cables; 39.0 cm (15.5 in.) with cables
Normal Operating Environment
> -5 C to +40 C (23 F to 104 F)
> 5% to 85% relative humidity,
non-condensing
Power
> DC power: -48 V to -60 V DC
> -60 m to 1,800 m (-197 ft. to
5,905 ft.) above sea level
Industry-Specific
Requirements
Telcordia (Bellcore)
> TR-NWT-000332
> GR-78-CORE
> GR-63-CORE
> GR-1089-CORE
ETSI
> ETS 300 019
> ETS 300 132-2
Telecom
> Telcordia (Bellcore) TR-NWT-1112
(Multimode)
> ITU G.957 (Optical STM-N)
>
Telcordia (Bellcore) TR-NWT-000499
(DS-N)
> AT&T Pub 62411 (DS-1)
> ITU G.703 (T1/E1/155 Mb/s)
> ITU G.707 (Synchronization Status)
Network Node Inter
face for Synchronous
Digital Hierarchy
> ITU G.825 Jitter/Wander, Digital Net-
works for Synchronous Digital Hierarchy
> Telcordia GR-253-CORE Issue 3
(Section 4: Physical Layer)
> Telcordia GR-253-CORE Issue 3
(Section 5.4 and 5.6: Network ITU-T
G.703 Physical Electrical Inter
faces
Requirements)
> ITU-T G.707 (SDH Mapping and
Overhead Requirements)
> ITU-T G.813 (Network Synchronization
Option 1(E rate))
> ITU-T G.823 (E-rate Jitter/Wander)
>
ITU-T G.824 (T-rate Jitter/Wander)
>
ITU-T G.825 (SDH Jitter/Wander)
> ITU-T G.957 (IR/LR/XLR)
> ANSI T1.403 (DS-1 Physical Layer)
> ANSI T1.404 (DS-3 Physical Layer)
> ANSI T1.102 (STM-1e)
> ANSI T1.105.06
The Alcatel 7670 RSP also supports
customer-specific qualification
requirements.
Alcatel 7670 RSP | Release 6.2
www
.alcatel-lucent.com
Alcatel, Lucent, Alcatel-Lucent, the Alcatel-Lucent logo, are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners. Alcatel-Lucent assumes no responsibility
for the accuracy of the information presented, which is subject to change without notice. © 12 2006 Alcatel. All rights reserved. 3CL 00469 0020 TQZZA Ed.12 21350
Qualification Summary
North and South America Europe, Middle East, Africa Asia, Pacific
Product Safety Approvals
CSA 60950-1 European Community IEC 60950-1
UL 60950-1 EN 60950-1 IEC 60825-1, -2
FDA/CDRH 21 CFR Part 1040 EN 60825-1, -2 AS/NZS 3260 and TS001
EMC Approvals
ICES-003 Class A European Community CISPR 22 Class A
EN 55022 Class A AS/NZS 3548 Class A
FCC Par
t 15 Class A
ETS 300 386 Class B
MIC Notice no. 2001-115
MIC Notice no. 2001-116
Network Attachment Approvals
IC CS-03 JATE Digital Services (Green Book)
ACTA TIA/EIA/IS-968 (formerly FCC Part 68) AS/ACIF S016
MIC Proclamation No: 1998-62
MIC Proclamation No: 1998-18
MIC Notice no. 2001-03