Alcatel-Lucent APX 1000 Network Card User Manual


 
APX
®
1000 Universal Gateway
11. APX
® 1000 Universal Gateway Module Options
WAN Access Modules
Circuit switching (ingress)
– 24-port Channelized T1/E1
– 8-port Channelized E1
– 8-port Channelized T1
– 1-port Channelized T3
Packet switching (egress)
– 2 or 4-port 10/100 fast Ethernet
Processor Modules
288-port MultiDSP
240-port MultiDSP
96-port MultiDSP
12. Power Requirements
Power budget AC
Total typical values per fully loaded chassis:
Input power per chassis: 200 W
Heat dissipation: 683 BTU/h
Current intake @ 100Vac input: 2.0 A**
Current intake @ 115Vac input: 1.7 A**
Current intake @ 230Vac input: 0.9 A**
Recommended MAX:
Input power per chassis: 381 W
Heat dissipation: 1300 BTU/h
Current intake @ 100Vac Input: 3.8 A**
Current intake @ 115Vac Input: 3.3 A**
Current intake @ 230Vac Input: 1.7 A**
Power budget DC
Total typical values per fully loaded chassis:
Input power per chassis: 200 W
Heat dissipation: 683 BTU/h
Current intake @ -48Vdc input: 4.2 A**
Current intake @ -40Vdc input: 5.0 A**
Recommended MAX:
Input power per chassis: 361 W
Heat dissipation: 1233 BTU/h
Current intake @ -48Vdc input: 7.5 A**
Current intake @ -40Vdc input: 9.0 A**
Configuration used for above:
1 x controller module, 3 x 288-port MultiDSP modules,
1 x 24-port T1 module,
1 x 2-port Ethernet module, 1 fan tray
** Per power supply
13. Operating Characteristics
Ambient operating temperature:
-0 C to 40 C (-5c to +55c for short term per GR63-
CORE)
Ambient storage temperature:
-40 C to +65 C
Relative humidity:
10% to 95% non-condensing
Operating altitude:
to 10,000 feet (3,050 M)
14. Regulatory Compliance
NEBS: Level 3 compliant, GR-63-CORE, GR-1089-
CORE, CLEI coded
EMC/EMI: FCC 15 Class A, R&TTE Directive (EN
55022, EN 300 386), Class A, EN 61000-3-2, EN
61000-3-3, AS/NZS 3548, Class A, CISPR 22 Class A,
VCCI Class A, CNS 13438 Class A
Safety: CSA NRTL (UL 1950, Third Edition), CSA
C22.2, No. 950, Third Edition, R&TTE Directive EN
60950 Including Amendments 1, 2, 3, 4, 11, IEC
60950 including Amendments 1, 2, 3, 4
Telecom: FCC Part 68, IC CS 03, JATE
To learn more about our comprehensive portfolio, please contact
your Alcatel-Lucent Sales Representative, Alcatel-Lucent Business
Partner or, visit our web site at www.alcatel-lucent.com
.
This document is provided for planning purposes only, and does
not create, modify or supplement any warranties which may be
made by Alcatel-Lucent relating to the products and/or
services described herein. The publication of information
contained in this document does not imply freedom from patent
or other protective rights of Alcatel-Lucent or third parties.
APX, True Access and MAX TNT are registered trademarks,
and MAX and NavisAccess are trademarks, of Alcatel-Lucent
Copyright 2004, 2008
Alcatel-Lucent
All rights reserved
APX v6.0108