Allied Telesis AT-AR040 Network Card User Manual


 
Hardware Reference 13
C613-03022-00 REV K
Figure 8: Example output from the show test command
For more complete testing, connect the BRI interface to an external ISDN test
device or NT mode device and use the enable bri ctest command and the
disable bri ctest command from the Integrated Services Digital Network (ISDN)
chapter the AlliedWare
®
Operating System Software Reference. This test will
execute conformance loopback tests and generate packets. If a test fails, please
contact your authorised Allied Telesis distributor or reseller.
Board ID Bay Board Name Host Id Rev Serial number
-------------------------------------------------------------------------------
Base 78 AR740 M1-15 46625812
PIC 38 0 AT-AR023-00 PIC Sync M1-1 5918255
NSM 95 AT-AR041-00 NSM 8BRI P1-3 46624968
Duration Details
Interface State Result Type (minutes) Data( %OK ) Control
-----------------------------------------------------------------------------
eth0 complete good trans 0 - - -
TP 1 good(100.0) -
ENDEC 1 good(100.0) -
MAC 1 good(100.0) -
eth1 complete good trans 0 - - -
TP 2 good(100.0) -
ENDEC 0 - - -
MAC 2 good(100.0) -
syn0 testing wait continuous RS-232dte 355 good(100.0) good
dce 355 good(100.0) good
X.21 dte 354 good(100.0) good .
dce 0 - - -
V.35 dte 354 good(100.0) good
dce 0 - - -
asyn0 complete check this screen - 4 - - -
asyn1 complete good - 4 good(100.0) good
BRI0 complete good - 4 good(100.0) -
BRI1 complete good - 4 good(100.0) -
BRI2 complete good - 4 good(100.0) -
BRI3 complete good - 4 good(100.0) -
BRI4 complete good - 4 good(100.0) -
BRI5 complete good - 4 good(100.0) -
BRI6 complete good - 4 good(100.0) -
BRI7 complete good - 4 good(100.0) -
-----------------------------------------------------------------------------