Allied Telesis AT-GS950/16 Switch User Manual


 
How to Start an AT-GS950/16 WEB Management Session
43
Returning the AT-S108 Management Software to the Factory Default
Values
This procedure returns all AT-S108 Management software parameters to
their default values and deletes all tagged and port-based VLANs on the
switch.
This procedure causes the switch to reboot. The switch does not forward
network traffic during the reboot process. Some network traffic may be
lost.
To return the AT-S108 Management software to the default settings, do
the following procedure:
1. From the Tools folder, select Reboot.
The Reboot Page is shown in Figure 14 on page 32.
2. For the Reboot Type field, use the pull-down menu to select one of
the following:
Factory Default
Resets all switch parameters to the factory default settings, including
the IP address, subnet mask, and gateway address.
Warning
This setting will cause the IP address to be reset to 192.168.1.1. You
will loose connectivity with the switch management software after
the reboot is completed
Factory Default Except IP Address
Resets all switch parameters to the factory default settings, but retains
the IP address, subnet mask, and gateway settings. If the DHCP client
is enabled, it remains enabled after this reset.
3. For the Reboot Status field, use the pull-down menu to select Start to
begin the reboot.
4. Click Apply.
The switch is rebooted. You must wait for the switch to complete the
reboot process before establishing your management session again.