Allied Telesis POTS24 Network Card User Manual


 
© 2006 Allied Telesis Inc.All rights reserved.Information in this document is subject to change without notice. All company names,logos,and product designs that are trademarks or registered trademarks are the property of their respective owners. 617-000038 Rev. D
POTS24 | AT-TN113-A 24 Port POTS Service Module
USA Headquarters | 19800 North Creek Parkway | Suite 200 | Bothell | WA 98011 | USA |T: +1 800 424 4284 | F: +1 425 481 3895
European Headquarters |Via Motta 24 | 6830 Chiasso | Switzerland | T: +41 91 69769.00 | F: +41 91 69769.11
Asia-Pacific Headquarters | 11 Tai Seng Link | Singapore | 534182 | T: +65 6383 3832 | F: +65 6383 3830
www.alliedtelesis.com
Ordering Information
**Where YY = 005 for 5 ft
= 010 for 10 ft
= 015 for 15 ft
= 020 for 20 ft
= 030 for 30 ft
= 040 for 40 ft
= 050 for 50 ft
= 060 for 60 ft
= 070 for 70 ft
= 080 for 80 ft
= 090 for 90 ft
iMAP 9x00 Chassis
Model Description Part #
iMAP 9700 17-slot chassis with DC power with faceplates AT-TN-250GF
iMAP 9700 17-slot chassis with DC power without faceplates AT-TN-250G
iMAP 9400 7-slot chassis with DC power with faceplates AT-TN-251GF
iMAP 9400 7-slot chassis with DC power without faceplates AT-TN-251G
MiniMAP 9101 3-slot mini chassis with DC power AT-TN-9101-A-80
MiniMAP 9102 3-slot mini chassis with AC power AT-TN-9102-A-XX*
POTS24
Model Description Part #
P
OTS24
2
4 ports, POTS Service Module
A
T-TN-113-A
iMAP Common Control
Model Description Part #
CFC24 24GbE switch controller card AT-TN-401-B
GE3 3x GbE WAN interface card AT-TN-301-A
CFC12 12GbE switch controller card AT-TN-408-A
Related iMAP Line Cards and Accessories
Model Description Part #
ADSL24 24-port, ADSL2+ Service Module (Annex A) AT-TN-112-A
CES8 8-port, T1/E1 Circuit Emulation Service Module AT-TN-119-A
PAC24 24-por
t,
POTS/ADSL2+ Combo w/Splitters, Anne
x A
AT-TN-123-A
Optimized Splitter Chassis Splitter Chassis, 3RU, 4 slot (North America only) AT-TN-S004-A
Optimized Splitter 24-port, Optimized Splitter card (North America only) AT-TN-S101-A
Optimized Splitter Cable ADSL24 to High P
erformance Splitter Cable
A
T-TN-C013-A-YY**
Standard Splitter Cable ADSL24 to Standard Splitter Cable AT-TN-C018-A-YY**
MDF Kit Terminal block to RJ-21 Male, 4 cables AT-TN-K022-A-YY**
CPE Attenuator ADSL2+ Attenuator AT-TN-S900-A
Filler Full size service slot filler plate AT-TN-M000-A
Interface Specifications
Number of ports: 24
Connector: RJ-21 (Female)
POTS Specifications
Talk Battery: 48 to 52Volts tip-ring on-hook
Ring Generator: 86-90Vrms, 20Hz into 15REN
2wire impedance: 900 ohms + 2.16uF complex
Frequency Response: 200 – 34000Hz flat
+/- 0.2db
Longitudinal balance: >45dB
Loop current: 26 – 28mA current limited
Loop range: 0 – 2000 ohms resistance
Loop signaling: Loopstart supervision,
superimposed ringing
Dialing support: DTMF, Dial Pulse
VoIP Specifications
CODEC: G.711, G.726-32k
Packetization: 10, 20, or 30ms
Echo: G.168 Echo Cancellation
Jitter buffer: Up to 150ms average delay
with 300ms buffer depth
Power Requirements
Maximum power: 55W
Environmental Conditions
Operating Temp: -40C to 65C
Storage Temp: -40C to 75C
Relative Humidity: 5% to 95%, non-condensing
Regulatory Approval
FCC Part 15 Class A/ANSI C63.4
EN 300 386 V1.3.1:2001-09/EN 55022:1998, Class A
VCCI Class A; ITE/ CISPR 22:1997 Class A
EN 300 386
V1.3.1:2001-09/EN 55022:1998,
Class
A
EN 300 386 V1.3.1:2001-09/EN 61000-4-3:1998
EN 300 386 V1.3.1:2001-09/EN 6100-4-6:1996
EN 300 386 V1.3.1:2001-09/EN 61000-4-4:1995
EN 300 386
V1.3.1:2001-09/EN 61000-4-5:1995
EN 300 386 V1.3.1:2001-09/EN 61000-4-2:1999
UL/cUL 60950:
IEC60950
NEBS Level 3, GR-1089 Issue 3, GR63 Issue 2
USDA RUS
GR-57-CORE
*
Where XX
= 10 for U.S
.
po
w
er cord
= 30 for U.K. power cord
= 40 for
Australia po
w
er cord
= 50 for Europe po
w