Allied Telesis x900 Advanced Gigabit Layer 3+ Expandable Switches Computer Hardware User Manual


 
Allied Telesis www.alliedtelesis.com
NETWORK RESILIENCY SOLUTIONS
| VCStack + Link aggregation
enable ssh server serverkey=1 hostkey=0 expirytime=1
logintimeout=60
add pki certificate="cer_name" location=cer_name.cer trust=true
set http server security=on sslkey=2 port=443
create log output=1 destination=syslog server=192.168.10.11
secure=yes message=20
add log output=1 filter=1 severity=>1
enable snmp
enable snmp authenticate_trap
create snmp community=public
enable snmp community=public trap
add snmp community=public manager=192.168.10.13
add snmp community=public traphost=192.168.10.13
enable ntp
add ntp peer=192.168.10.3
Remote management sessions must use SSH and/or
HTTPS
All log messages are sent to a syslog server.
Higher-severity log messages are also buffered on the
switch itself
Allow read-only SNMP monitoring from one management
station. Send traps to that same management station
System time is provided from an NTP server