Altinex 400-0226-003 Switch User Manual


 
MULTI-TASKER
9
9
Example:
If one MT105-110/111 card is in slot #2 of unit
3:
When sending command [VERC2U3], the Multi-
Tasker™ Enclosure will return feedback as
MT105-111 690-0126-011.
2. [C]
This command displays the status of the card
and connections of the Matrix Switcher.
Command Format: [CnUi]
Cn = card ID (n = a slot # from 1 to 19)
(1 to 8 for MT100-101 or 1 to 4 for MT100-106)
Ui = unit id (i = 0 to 9) (refer to the MT100-100
user’s guide for explanation)
Example:
If one MT105-110/111 card is in slot #2 of unit 3
with output 1, 2 and 3 ON:
When sending command [C2U3], feedback will
be returned as:
Config:16X8
In1 Out1 ON
In2 Out2 ON
In1 Out3 ON
In2 Out4 OFF
In8 Out5 OFF
In7 Out6 OFF
In10 Out7 OFF
In16 Out8 OFF
Description of Feedback:
Input1 is connected to Output1 and Output1 is
enabled
Input2 is connected to Output2 and Output2 is
enabled
Input1 is connected to Output3 and Output3 is
enabled
Input2 is connected to Output4 and Output4 is
disabled
Input8 is connected to Output5 and Output5 is
disabled
Input7 is connected to Output6 and Output6 is
disabled
Input10 is connected to Output7 and Output7 is
disabled
Input16 is connected to Output8 and Output8 is
disabled
Note: If there is no card in slot #2 of unit
3,sending the [C2U3] command will not return
any feedback.
ERROR CODES
ER01: CPU Error
This type of error indicates that the CPU is not
working properly.
ER02: I²C Communication Error
This means that the communication between
the MT105-110/(111) card and its serial device
has failed.
ER03: RS485 Communication Error
This type of error is a communication error
between the MT105-110/(111) card and the
controller of the Multi-Tasker™ Enclosure.
[CiS]
This command saves card status such as
ON/OFF, IN/OUT connection as default settings
3. [IO]
This command will connect input x with output y,
but the user needs to use the [ON] command to
enable this output.
Command Format: [IxOyCnUi]