Altinex MT105-110 Switch User Manual


 
MULTI-TASKER
13
13
10. [RD]
This command displays the members in each
group.
Command Format: [RDGkUi]
k = group number (k = # from 1-9)
i = unit number (i = # from 0-9)
member = C1 - C19 (card 1 to 19) (1 to 8 for
MT100-101 or 1 to 4 for MT100-106)
Example:
To read member data for group 5 of unit 1, send
the [RDG5U1] command. The system will return
feedback as C1C2C3 G5U1
11. [HELP]
This command displays all available commands
for RS-232 control.
7.3.SUMMARY OF COMMANDS.
1) [VER]: Receives software version
2) [C]: Receives status of the card
3) [IO]: Connects the input to the output
4) [ON]: Turns on one or more outputs for a
single card or a group of cards
5) [OFF]: Turns off one or more outputs for
a single card or a group of cards
6) [SW]: Switch (outputs the preloaded
buffer)
7) [WR]: Groups multiple cards
8) [CLR]: Clears members of a single group
or all groups
9) [G]: Requests group data
10) [RD]: Displays the members in each
group.
11) [HELP]: Displays all commands
TROUBLESHOOTING GUIDE 8
We have carefully tested and have found no
problems in the supplied MT105-110/(111);
however, we would like to offer suggestions for the
following:
NO DISPLAY
Cause 1: The source has a problem.
Solution: Check the source and make sure, that
there is a signal present and all
source connections are correct. If the
source is working and there is still no
display, see Cause 2.
Cause 2: The card input is not selected.
Solution: Select the card input. See RS-232
accessible commands in section 7.If
no display is present see Cause 3.
Cause 3: Cable connections to the destination
are incorrect.
Solution 1: Make sure that cables are connected
properly. Also, make sure that the
continuity and wiring are good. If there
is still no display present, see Cause
4.
Cause 4: The display has a problem.
Solution 1: Make sure that the display is powered.
If there is still no display, call
ALTINEX at (714) 990-2300.