MULTITASKER
400-0371-004
8
Cause 3: The path is not selected.
Solution: Make sure the input to output path is
correctly selected.
For example, Input 2 is connected to
Output 1 in the Matrix Engine status.
Physically, the source signal should
be connected to Input 2 and the
display cable should be connected
to Output 1. See RS-232 accessible
commands in Section 7 of the
MT107-104 User’s Guide for
command details.
If no display is present, see
Cause 4.
Cause 4: Cable connections are incorrect.
Solution: Make sure that cables are properly
connected. Also, make sure that the
continuity and wiring are good. If
there is still no display present, see
Cause 5.
Cause 5: The display has a problem.
Solution: Make sure the display is powered
and is turned on. If there is still no
display, please call ALTINEX at
(714) 990-2300.
ALTINEX POLICIES 9
9.1 LIMITED WARRANTY/RETURN POLICIES
Please see the ALTINEX website at
www.altinex.com for details on warranty and
return policies.
9.2 CONTACT INFORMATION
ALTINEX, Inc.
592 Apollo Street
Brea, CA 92821 USA
TEL: 714 990-2300
TOLL FREE: 1-800-ALTINEX
WEB: www.altinex.com
E-MAIL: solutions@altinex.com