Panel Calibration, Setup, and System Connection
1. Press down and hold both the bottom-left and the bottom-right
pushbuttons simultaneously for10 seconds to open the Calibration page.
2. Calibrate the panel by pressing over the two cross-hairs. When done, a
"Calibration Successful..." message appears.
3. Press anywhere on the screen to return to the Setup page.
4. From the Setup page, touch the Protected Setup button and enter the
panel password into the on-screen keypad. Factory default is 1988.
5. Press the blue Device Number field to open the Device Number
keypad and enter a Device Number value for the panel.
Factory default is 10001.
6. Press Done when finished entering the device number.
7. Press the on-screen Reboot button to restart the panel.
8. From the Setup > Protected Setup page, touch the Wireless
Connection button to open the Wireless Connection page (FIG. 3).
Note: The signal strength bargraph should show a connection to a Wireless
Access Point. If there is no signal or IP Address displayed; configuration of your
network could be required.
Configuring the MVP-7500 Panel for Unsecured Access
The MVP panel contains an internal 802.11b (Type I) wireless compact flash
card that is used for communication with 802.11b Wireless Access Points.
1. Select Protected Setup > Wireless Connection.
2. Locate the Wireless Settings section of the Wireless Connection page.
Note: The MVP-7500 wireless communication settings are defaulted to an
Open Authentication system. An OPEN system allows the MVP to
communicate with the first available Wireless Access Point.
3. Touch the Network Name (SSID) field (FIG. 3).
4. From the Service Set Identifier keyboard, either:
Enter the SSID name assigned to the specific Wireless Access Point
(case sensitive) or
Leave this field blank to communicate with the first available Wireless
Access Point.
5. Verify the Authentication field reads Open (default).
6. Press the Encryption field until it reads Clear Text (default). The
remaining Wireless Settings fields are then greyed-out and read-only.
7. Toggle the DHCP/Static field (within the left IP Settings section) until it
reads DHCP.
8. Touch the Protected Setup button to navigate to the Protected Setup
page.
9. Press the on-screen Reboot button to both restart the panel and save
your changes.
10. Return to the Secondary Connection page to verify that the signal
strength quality bargraph is On (indicating a signal).
Note: The signal strength bargraph should show a connection to a
Wireless Access Point. If there is no signal or IP Address displayed;
configuration of your network could be required.
Configuring the MVP-7500 Panel for Secured Access
1. Select Protected Setup > Wireless Connection.
2. Locate to the Wireless Settings section of the Wireless Connection page.
3. Touch the Network Name (SSID) field (FIG. 3).
4. From the Service Set Identifier keyboard, enter the SSID name used on
your Wireless Access Point.
5. Press the Encryption field until it reads WEP64 or WEP128. The
64/128 selection reflects the bit-level of encryption security previously
configured on your target Access Point.
6. Press the Default Key field until the value matches the identifier value of
the key entered into the Wireless Access Point.
The panel’s Default Key value must match the Key value being used on
the WAP. For example: Default Key 1 on the panel must match the Key
value selected on the Wireless Access Point. You can select from up to
four keys.
WEP will not work unless the same default key is set on both the
panel and the Wireless Access Point.
7. Under the title WEP Keys section, touch the Key button that
corresponds to the Default WEP Key number being used on the Wireless
Access Point to launch the WEP Key # keyboard.
8. Using this keyboard, enter the same Current Key value being used on the
Wireless Access Point.
9. Click Done when you are finished entering the Current Key for the
selected WEP Key.
Note: If your target Wireless Access Point does not support passphrase key
generation, and has previously been setup with a manually entered WEP KEY,
you will have to manually enter that same WEP key on your panel.
10. Toggle the DHCP/Static field (within the IP Settings section) until it reads
DHCP.
11. Touch the Protected Setup button to navigate to the Protected Setup
page.
12. Press the on-screen Reboot button to both restart the panel and save
your changes.
13. Return to the Secondary Connection page to verify that the link
quality bargraph is On (indicating a signal).
Master Connection Section
The default method used for Master connection is Ethernet.
First - Setup the Master Connection
To configure Ethernet communication:
1. Under the Master Connection column toggle the Connection Type field
until the word Ethernet is shown.
2. Press the Mode button:
URL - Enter the System Number (zero for an unknown System
Number) and the IP/URL of the Master (Master Port Number is defaulted
to 1319).
Listen - Add the MVP’s IP Address into the URL List of the Master (using
NetLinx Studio). This mode sets the MVP panel to "listen" for broadcasts
from the Master (using the panel IP from its URL list).
Auto - Enter the System Number of the NetLinx Master. This mode
instructs the MVP to search for a Master that uses the same System
Number (assigned within the Master Connection
section) and that resides on the same subnet.
Note: Refer to the Configuring your NetLinx Master for Communication section
of the MVP Wireless Modero Touch Panels Instruction Manual for detailed
Mode parameter information.
Second - Setup the IP Settings (Panel Communication)
Toggle the on-screen DHCP/Static button to select the appropriate setting for
your system.
DHCP - With this setting, other settings are greyed-out and do not apply.
Typically the Host Name can be left blank. These fields (“pulled” from the
Ethernet connection) are filled-in by the panel after the unit is rebooted.
Static IP - With this setting, you must enter the network information as
provided by your Network Administrator.
Note: When done, press the on-screen Reboot button. (on the Protected
Setup page) after any changes are made to the Communication
Parameters.
FIG. 3 Wireless Connection page (MVP wireless connectivity page)
Wireless
Compact
Flash Card
connection
info.
Panel
connection
information
SSID field