Anton/Bauer HyTRON 140 Power Supply User Manual


 
SERVICE
In the unlikely event a HyTRON battery fails to deliver acceptable performance,
it must be returned to the Anton/Bauer Customer Support Department, the only
facility qualified and equipped to service the InterActive 2000 HyTRON batteries
and calibrate the electronic components and sensors. Any attempt by the user or
any other unauthorized persons to service this battery will surely result in
improper calibration of the electronic components resulting in severe battery
damage and/or safety hazards to the operator, in addition to voiding any/all
remaining unconditional or pro-rated warranty conditions.
Therefore:
1. DO NOT attempt to service this battery under any circumstances.
2. DO NOT send this battery for service to anyone other than the
Anton/Bauer Service Department.
3. DO NOT rebuild this battery - At the end of its useful life contact the
Anton/Bauer Service Department.
SPECIFICATIONS
HYTRON 140 HYTRON 100 HYTRON 50
OUTPUT VOLTAGE
14.4v Nominal
12 ~ 16.8v Operating
14.4v Nominal
12 ~ 16.8v Operating
14.4v Nominal
12 ~ 16.8v Operating
CAPACITY
(CELL CAPACITY)
140 WH Nominal
(10 AH Rated)
100 WH Nominal
(7 AH Rated)
50 WH Nominal
(3.5 AH Rated)
FUSE
12.5amp/125volt 12.5amp/125volt Internal (7amp)
RECOMMENDED OPERATION
15-100 watts 15-100 watts 15-50 watts
(MAXIMUM DISCHARGE RATE) (175 watts) (175 watts) (75 watts)
TYPICAL RUN-TIME
@ 20w – 7 hrs.
@ 25w – 5.6 hrs.
@ 40w – 3.5 hrs.
@ 20w - 5 hrs.
@ 25w - 4 hrs.
@ 40w – 2.5 hrs.
@ 10w - 5 hrs.
@ 20w - 21/2 hrs.
@ 25w - 2 hrs.
WEIGHT
5.5 lbs 5.5 lbs 1.9 lbs
SIZE
5
5/16 x 4 1/2 x 3 3/4 5 5/16 x 4 1/2 x 3 3/4 5 1/4 x 3 1/2 x 2 1/8
14