APC 66124 Network Card User Manual


 
3402231500/AC
The Network Management Teleservice Card (66124) is
recommended for central UPSs protecting entire networks or for UPS
units backing up critical loads.
With the card installed, the UPS has its own IP address and uses the
local computer capabilities to:
supply web pages (http or https (SSL)) with information on status
conditions and measurements/settings/alarms,
integrate an SNMP-based NMS such as HP OpenView, IBM Tivoli
Netview and Computer Associates Unicenter,
communicate with shutdown modules installed on the protected
servers (Network Shutdown Module),
send e-mail and SMS messages,
control the ON/OFF function of the UPS and the outlets,
monitor the Environment Sensor,
Access the Teleservice solution for remote monitoring and
maintenance services of your UPS.
One Network Management Teleservice Card (66124),
One serial cable for configuration (3402226700),
One phone cable for teleservice (3402226800),
One installation manual (34022315EN),
One Teleservice information form (3402228500),
PHONE port
ETHERNET port
Service port (Sensor/RS485)
Default settings, sensor configuration :
INTRODUCTION
The Network Management Teleservice Card must be
installed and used in accordance with manufacturer
instructions.
UNPACKING AND CHECKS
Installation manual
Network
Management
Teleservice Card
(66124)
66108
Settings/Sensor
ETHERNET
UPS data RS232
100M
10M
Settings/Sensor
Settings/Sensor
Settings/Sensor
Settings/Sensor
66124
S
ettin
g
s/S
en
so
r
E
TH
E
R
N
E
T
U
P
S
d
ata
R
S
23
2
10
0
M
1
0
M
S
e
ttin
g
s
/S
en
so
r
S
ettin
g
s/S
e
n
so
r
S
e
t
t
i
n
g
s
/
S
e
n
s
o
r
S
e
t
t
in
g
s
/S
e
n
s
o
r
OVERVIEW
INDICATIONS
LED Colour Status Description
UPS Data Green OFF
ON
Flashing
Card not connected to phone
network
Card connected to phone
network, but no activity
Port is sending/receiving
CD Orange
OFF
ON
Flashing
Modem is not connected
Modem is connected
Modem is connecting
LED Colour Status Description
ACT Green OFF
ON
Flashing
Card not connected to network
Card connected to network, but
no activity
Port is sending/receiving
100M Orange
OFF
ON
Port operating at 10 Mbits/s
Port operating at 100 Mbits/s
LED Colour Status Description
Sensor Green OFF
ON
Flashing
Card starting
Card ready
Communication with environment
Sensor is operational
RS485 Orange
OFF
Flashing
Flashing
every seconds
Settings mode activated
Port is sending/receiving
Communication fault or
configuration errors
SWITCHES SETTING
MAC adress
PHONE port:
Green LED : Phone communication
with the UPS
Orange LED : Modem connection
ETHERNET port:
Green LED : Connection + activity
Orange LED : 10/100 M
Service port (Sensor/RS485):
Green LED : Communication with
the UPS
Orange LED :RS232 activity
Catalogue number
66124
SENSOR/RS 485
ETHERNET
( Settings)
100M
UPS Data CD
PHONE
RESET
AC
T
000623001C07
000623001C07
SA2
1
8
3
SA1
1
8
3
OFF
ON
OFF
ON