APC 1400 Switch User Manual


 
16
420 VA 650 VA 1000 VA 1400VA
Telephone line surge protection, 1.2 µs/50
waveform
±6kV
Telephone line protection let through when
subjected to a 500A surge (8/20 µs
waveform, L-L, L-G)
<5%
10Base-T protection let through (from
6kV/125A normal mode surge)
<1%
Operating temperature 0 to +40 °C (+32 to +104 °F)
Storage temperature (see section 11) -15 to +45 °C (+5 to +113 °F)
Operating and storage relative humidity 0 to 95%, non-condensing
Operating elevation 0 to +3,000 m (0 to +10,000 ft)
Storage elevation 0 to +15,000 m (0 to +50,000 ft)
Electromagnetic immunity IEC 801-4 level IV, 801-5 level III
Audible noise at 1 m (3 ft) <45 dBA <50 dBA
Size (H x W x D)
16.8 x 11.9 x 36.1 cm
(6.6 x 4.6 x 14 in.)
21.6 x 17 x 43.9 cm
(8.5 x 6.7 x 17.3 in.)
Weight - net (shipping)
7.9 (9.6) kg
17.5 (21.1) lb.
11.3 (12.2) kg
24.9 (26.8) lb.
18.8 (21) kg
41.5 (46) lb.
24.1 (26.1) kg
53 (57.5) lb.
Safety and approvals UL 1778, UL 497A, CSA 107.1, FCC part 68, IEEE 802.3
EMC verification FCC/DOC Class B certified