9APC A/V G-Type Rack Power Filter: Operation
Power Threshold. The amount of power used by a device in Sleep or Standby mode varies between
devices. It may be necessary to adjust the threshold at which the Master outlet signals the Controlled
outlets to shut down.
1. Ensure a master device is connected to the Master outlet. Put that device into Sleep or Standby
mode, or turn it OFF.
2. Press
STATUS and hold for three seconds.
3. The G50 unit will display now recognize the threshold level of the Master device and save it as
the new threshold setting. Use the
UP or DOWN arrow key to adjust the power threshold.
Green Function. Use the Up and Down arrow buttons to enable or disable the green function. The
Green Function allows you to utilize the
MASTER and CONTROLLED outlets. When the device plugged into
the
MASTER outlet goes into Sleep or Standby mode, or turns off, the equipment that is connected to the
CONTROLLED outlets will also turn off, saving electricity.
Utility Rate. Enter electrical power utility rate in cents/kWh (USD only). The G50B-20A2 unit will use
this to calculate the savings accumulated when using the green function
MASTER and Controlled outlets.
Contact Information. This screen can be customized to include the contact information of the A/V
dealer or installer. Push the
STATUS button to move the cursor to the next letter and use the Up and Down
arrow buttons to scroll to the appropriate letter.
Maximum and Minimum Voltages. Set the voltage range in which the unit should normally operate.
The unit will protect connected equipment from high and low voltages that are not safe for operation.
Clear Saved Power. Reset the counter for the amount of power saved that has been saved by the unit.
POWER THRESHOLD:
10 W
TRACKING POWER
SUCCESSFULLY
GREEN FUNCTIONS
DISABLE
UTILITY RATE
12 cents/kWh
1-888-8827228
WWW.APCAV.COM
MAX UPPER VOLT:
140V (132-140)
MIN LOWER VOLT:
92V (92-100)
CLEAR SAVED PWR
YES