Specifications
t
Warranty
The standard warranty is three (3) years from the date of purchase, valid in European Community. For all other regions, the standard warranty
is two (2) years from the date of purchase. APC’s standard procedure is to replace the original unit with a factory reconditioned unit.
Customers who must have the original unit back due to the assignment of asset tags and set depreciation schedules must declare such a need at
first contact with an APC Technical Support representative. APC will ship the replacement unit once the defective unit has been received by
the repair department, or cross-ship upon the receipt of a valid credit card number. The customer pays for shipping the unit to APC. APC pays
ground freight transportation costs to ship the replacement unit to the customer
.
APC Worldwide Customer Support
Model BR1200GI BR1500GI
VA 1200 VA 1500 VA
Maximum Load 720 W 865 W
Nominal Input Voltage 230 V
Online Input Voltage Range 176 - 294 V
Automatic Voltage Regulation (188-216) +11.2%
(252-282) -11.2%
Frequency Range 50/60 Hz ± 1 Hz
On-battery Waveshape Step-approximated sine-wave
Typical Recharge Time 8 hours
Transfer Time 10 ms, maximum
Operating Temperature 0
to 40C (32 to 104F)
Storage Temperature -15
to 45C (23 to 113F)
Unit Dimensions 30.1 × 11.2 × 38.2 cm (11.9 × 4.4 × 15.0 in)
Unit Weight 12.8 kg (28.2 lbs) 13.4 kg (29.5 lbs)
Interface Serial, USB
On-Battery Runtime Go to: www.apc.com
EMI Classification CE, C-Tick, KETI
Approvals CE, TUV-GS, GOST, A-Tick, KETI, TISI
Internet http://www.apc.com
Worldwide +1 888 272-3858
Replacement Battery
The battery cartridge typically lasts 3 to 6 years, a shorter
period if subjected to frequent outages or elevated
temperatures. Battery replacement part for Back-UPS Pro 1200
and 1500 is APCRBC124. Please recycle spent battery
cartridges.
Service
If the Back-UPS arrived damaged, notify the carrier.
If the Back-UPS requires service, do not return it to the dealer.
1. Consult the Troubleshooting section to eliminate common
problems.
2. If the problem persists, go to http://www.apc.com/support/.
3. If the problem still persists, contact APC Technical Support.
Have the Back-UPS model number, serial number and date of
purchase available. Be prepared to troubleshoot the problem
with an APC Technical Support representative.
If this is not successful, APC will issue a Return Merchandise
Authorization (RMA) number and a shipping address.